Literature DB >> 19615518

Alternative method for measurement of albumin/creatinine ratio using spectrophotometric sequential injection analysis.

Weena Siangproh1, Norio Teshima, Tadao Sakai, Shuji Katoh, Orawon Chailapakul.   

Abstract

A simple, automatic and practical system for successive determination of albumin and creatinine has been developed by combining sequential injection analysis (SIA) and highly sensitive dye-binding assays. Albumin detection was based on the increase in the absorbance due to complex formation between albumin and eosin Y in acidic media. The absorbance of the complex was monitored at 547 nm. For the creatinine assay, the concentration of creatinine was measured by reaction with alkaline picrate to form a colored product which absorbs at 500 nm. The influences of experimental variables such as effects of pH, reagent concentration, standard/sample volume and interferences were investigated. Under optimal conditions, the automated method showed linearity up to 20 mg L(-1) for albumin and 100 mg L(-1) for creatinine. The 3 sigma detection limits were 0.6 and 3.5 mg L(-1) for albumin and creatinine, respectively, and the relative standard deviations (n=10) were 2.49% for 20 mg L(-1) albumin, and 3.14% for 20 mg L(-1) creatinine. Application of the proposed method to the direct analysis of urinary samples yielded results which agreed with those obtained from the Bradford protein assay and a creatinine enzymatic assay according to a paired t-test. The results obtained should be a step towards developing a fully automated and reliable analytical system for clinical research, which requires direct determination of albumin and creatinine and/or its ratios.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19615518     DOI: 10.1016/j.talanta.2008.12.068

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

Review 1.  Recent advances in nephropathy biomarker detections using paper-based analytical devices.

Authors:  Akhmad Sabarudin; Setyawan P Sakti; Hani Susianti; Nur Samsu; Ika O Wulandari; Yudit Oktanella; Dewi Anggraeni
Journal:  Anal Sci       Date:  2022-02-28       Impact factor: 2.081

2.  Microfluidic Sliding Paper-Based Device for Point-of-Care Determination of Albumin-to-Creatine Ratio in Human Urine.

Authors:  Szu-Jui Chen; Chin-Chung Tseng; Kuan-Hsun Huang; Yu-Chi Chang; Lung-Ming Fu
Journal:  Biosensors (Basel)       Date:  2022-07-07

3.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

4.  Determination of Albumin, Glucose, and Creatinine Employing a Single Sequential Injection Lab-at-Valve with Mono-Segmented Flow System Enabling In-Line Dilution, In-Line Single-Standard Calibration, and In-Line Standard Addition.

Authors:  Kanokwan Kiwfo; Wasin Wongwilai; Tadao Sakai; Norio Teshima; Kate Grudpan
Journal:  Molecules       Date:  2020-04-04       Impact factor: 4.411