| Literature DB >> 19609394 |
Bo Wei1, Dong Liang, Theodore R Bates.
Abstract
A simple, specific, sensitive, and rapid high performance liquid chromatography (HPLC) method for the determination of griseofulvin in small volumes of rat plasma was developed and validated using warfarin as an internal standard. Biological sample preparation involved simple extraction with acetonitrile, followed by dilution with aqueous mobile phase buffer (20 mM sodium dihydrogen phosphate, pH 3.5) to eliminate any chromatographic solvent effects. Griseofulvin and warfarin were baseline separated and quantitated on a C(18) reversed phase column (4.6 x 150 mm, 3.5 microm), using a mobile phase composed of a 20 mM aqueous solution of sodium dihydrogen phosphate-acetonitrile (55:45, v/v, pH 3.5) delivered at a flow rate of 1.0 mL/min, and with fluorescence detection (lambda(excitation) = 300 nm, lambda(emission) = 418 nm). The method was proven to be linear over a plasma griseofulvin concentration range of 10 to 2500 ng/mL with a mean correlation coefficient of 0.9996. The intra-day and inter-day accuracy (relative error) were in the range of 0.89% to 9.26% and 0.71% to 7.68%, respectively. The within-day precision (coefficient of variation) was less than 3.0% and the between-day precision was less than 7.5%. The mean recovery of griseofulvin from rat plasma was found to be 99.2%. The limit of detection (LOD) and the limit of quantification (LOQ) of griseofulvin were determined to be 1 ng/mL and 10 ng/mL, respectively. The developed method was successfully applied to quantitatively assess the pharmacokinetics of griseofulvin in rats following a single 50 mg/kg oral dose of the drug.Entities:
Keywords: HPLC; fluorescence; griseofulvin; pharmacokinetics; rat plasma
Year: 2008 PMID: 19609394 PMCID: PMC2701169 DOI: 10.4137/aci.s953
Source DB: PubMed Journal: Anal Chem Insights ISSN: 1177-3901
Figure 1.Chemical structure of griseofulvin (C17 H17 ClO6).
Figure 2.Representative HPLC Chromatograms for (A) a standard buffer solution spiked with griseofulvin (500 ng/mL) and the IS (warfarin; 50 μg/mL); (B) blank rat plasma; (C) blank rat plasma spiked with griseofulvin (500 ng/mL) and the IS (50 μg/mL); (D) rat plasma sample obtained 5 hr after a 50 mg/kg oral dose of griseofulvin; (E) Limit of detection (LOD) of griseofulvin in rat plasma: 1 ng/mL; and (F) Limit of quantification (LOQ) of griseofulvin in rat plasma: 10 ng/mL. Peak 1 = griseofulvin and Peak 2 = IS.
Figure 3.Mean plasma concentration–time profile of griseofulvin (ng/mL) following an oral dose of 50 mg/kg to six Sprague-Dawley rats.