Literature DB >> 17196449

Electrospray ionization LC-MS/MS validated method to quantify griseofulvin in human plasma and its application to bioequivalence study.

Hiren N Mistri1, Arvind G Jangid, Mallika Sanyal, Pranav Shrivastav.   

Abstract

A simple, sensitive and rapid liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated to quantify griseofulvin in human plasma using propranolol hydrochloride as internal standard (IS). Samples were prepared using solid phase extraction and analysed without drying and reconstitution. The analytes were chromatographed on Hypersil, hypurity C18 reverse phase column under isocratic conditions using 0.05% formic acid in water:acetonitrile (30:70, v/v) as the mobile phase. Total chromatographic run time was 3.0 min. Quantitation was done on a triple quadrupole mass analyzer API-3000, equipped with turbo ion spray interface and operating in multiple reaction monitoring (MRM) mode to detect parent-->product ion transition for analyte and IS. The method was validated for sensitivity, matrix effect, accuracy and precision, linearity, recovery and stability studies. Linearity in plasma was observed over the concentration range 20-3000 ng/mL for griseofulvin. Lower limit of quantification (LLOQ) achieved was 20 ng/mL with precision (CV) less than 10% using 5 microL injection volume. The absolute recovery of analyte (87.36%) and IS (98.91%) from spiked plasma samples was consistent and reproducible. Inter-batch and intra-batch coefficients of variation across four validation runs (LLOQ, LQC, MQC and HQC) was less than 7.5%. The accuracy determined at these levels was within +/-4.2% in terms of relative error. The method was applied to a pilot bioequivalence study of 500 mg griseofulvin tablet in six healthy human subjects under fed condition.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 17196449     DOI: 10.1016/j.jchromb.2006.12.003

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Development of Surface Molecularly Imprinted Polymers as Dispersive Solid Phase Extraction Coupled with HPLC Method for the Removal and Detection of Griseofulvin in Surface Water.

Authors:  Kamran Bashir; Zhimin Luo; Guoning Chen; Hua Shu; Xia Cui; Wen Li; Wang Lu; Qiang Fu
Journal:  Int J Environ Res Public Health       Date:  2019-12-24       Impact factor: 3.390

2.  Rapid and Simultaneous Analysis of Multiple Classes of Antimicrobial Drugs by Liquid Chromatography-Tandem Mass Spectrometry and Its Application to Routine Biomedical, Food, and Soil Analyses.

Authors:  Anjali Mishra; Yashpal Singh Chhonker; Amol Chhatrapati Bisen; Yarra Durga Prasad; Sachin Laxman Tulsankar; Hardik Chandasana; Tushar Dey; Sarvesh Kumar Verma; Veenu Bala; Sanjeev Kanojiya; Sandeep Ghatak; Rabi Sankar Bhatta
Journal:  ACS Omega       Date:  2020-12-04

3.  Development and validation of a HPLC method to determine griseofulvin in rat plasma: application to pharmacokinetic studies.

Authors:  Bo Wei; Dong Liang; Theodore R Bates
Journal:  Anal Chem Insights       Date:  2008-08-27

4.  Formulation and evaluation of cyclodextrin-based nanosponges of griseofulvin as pediatric oral liquid dosage form for enhancing bioavailability and masking bitter taste.

Authors:  Samia M Omar; Fares Ibrahim; Aliaa Ismail
Journal:  Saudi Pharm J       Date:  2020-02-03       Impact factor: 4.330

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.