Literature DB >> 19606188

Intraocular pressure changes in a Nigerian population--effects of tracheal tube and laryngeal mask airway insertion and removal.

J O Igboko1, I Desalu, F B Akinsola, O T Kushimo.   

Abstract

OBJECTIVES: Laryngoscopy and tracheal intubation lead to acute elevation in intraocular pressure (IOP); the ocular hypertensive response. The Laryngeal mask airway prevents sudden surges in IOP. We compared IOP changes to the insertion and removal of the Laryngeal mask airway (LMA) and the endotracheal tube (ETT). PATIENTS AND METHODS: Seventy ASA I and II patients aged 18 to 60 years at the Lagos University Teaching Hospital between January and December 2003 were randomly allocated to receive either an LMA or ETT for airway management. Anaesthesia was induced with propofol and atracurium. Intraocular pressure was measured by applanation tonometry post induction (baseline) and prior to removal (pre-extubation), after insertion or removal (0 minute), at 1,2,3,5 and 10 minutes after insertion or removal.
RESULTS: Insertion of the airway device caused an immediate rise in IOP of 4.6% in the LMA group (from 13.1 +/- 2.4 to 13.7 +/- 2.4 mmHg) and 49.2 in the ETT group (from 12.0 +/- 2.5 to 17.9 +/- 4.0 mmHg) (p<0.001). Removal of the airway device caused an immediate rise in IOP of 14.6 in the LMA group (from 11.26 +/- 2.4 to 12.9 +/-2.4 mmHg) and 50.3 in the ETT group (from 11.37 +/- 2.0 to 17.1 +/- 3.3 mmHg) (p<0.001). IOP thereafter declined towards baseline in both groups. Cardiovascular responses accompanied IOP changes. The mean insertion time was 39.8 +/- 9.1 seconds (ETT) vs 31.5 +/- 4.4 seconds (LMA). (p<0.001) Cough (17.1) and mild laryngeal spasm (2.9) occurred in the ETT group only following removal.
CONCLUSION: The LMA produced better IOP stability following its insertion and removal compared to the tracheal tube.

Entities:  

Mesh:

Year:  2009        PMID: 19606188

Source DB:  PubMed          Journal:  Niger Postgrad Med J


  5 in total

1.  Comparison of Regional vs. General Anesthesia for Surgical Repair of Open-Globe Injuries at a University Referral Center.

Authors:  Andrew J McClellan; Jacquelyn J Daubert; Nidhi Relhan; Kimberly D Tran; Harry W Flynn; Steven Gayer
Journal:  Ophthalmol Retina       Date:  2017-01-19

2.  Comparison between rocuronium and suxamethonium muscle relaxants in ocular trauma surgery.

Authors:  Po Agbamu; Id Menkiti; I Desalu; Ot Kushimo; Fb Akinsola
Journal:  J West Afr Coll Surg       Date:  2013-01

3.  A comparison of intraocular pressure and hemodynamic responses to insertion of laryngeal mask airway or endotracheal tube using anesthesia with propofol and remifentanil in cataract surgery.

Authors:  Mohsen Ziyaeifard; Rasoul Azarfarin; Gholamreza Massoumi
Journal:  J Res Med Sci       Date:  2012-06       Impact factor: 1.852

4.  Effect of cisatracurium versus atracurium on intraocular pressure in patients undergoing tracheal intubation for general anesthesia.

Authors:  Mitra Jabalameli; Hassan Ali Soltani; Jalal Hashemi; Mojtaba Rahimi
Journal:  J Res Med Sci       Date:  2011-03       Impact factor: 1.852

5.  Effect of Laryngeal Mask Air Way Insertion versus Endotracheal Intubation over Hemodynamic Responses in Pediatrics Patient Who Underwent Ophthalmic Surgery at Menelik II Hospital, Addis Ababa: A Prospective Observational Study Design.

Authors:  Mohammed Suleiman Obsa; Azeb Lencha Sholla; Betelhem Girma Baraki; Getahun Dendir Welde; Temesgen Bati Gelgelu; Melese Meleku Kuruche
Journal:  Anesthesiol Res Pract       Date:  2020-06-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.