Literature DB >> 19601617

Mass cytometry: technique for real time single cell multitarget immunoassay based on inductively coupled plasma time-of-flight mass spectrometry.

Dmitry R Bandura1, Vladimir I Baranov, Olga I Ornatsky, Alexei Antonov, Robert Kinach, Xudong Lou, Serguei Pavlov, Sergey Vorobiev, John E Dick, Scott D Tanner.   

Abstract

A novel instrument for real time analysis of individual biological cells or other microparticles is described. The instrument is based on inductively coupled plasma time-of-flight mass spectrometry and comprises a three-aperture plasma-vacuum interface, a dc quadrupole turning optics for decoupling ions from neutral components, an rf quadrupole ion guide discriminating against low-mass dominant plasma ions, a point-to-parallel focusing dc quadrupole doublet, an orthogonal acceleration reflectron analyzer, a discrete dynode fast ion detector, and an 8-bit 1 GHz digitizer. A high spectrum generation frequency of 76.8 kHz provides capability for collecting multiple spectra from each particle-induced transient ion cloud, typically of 200-300 micros duration. It is shown that the transients can be resolved and characterized individually at a peak frequency of 1100 particles per second. Design considerations and optimization data are presented. The figures of merit of the instrument are measured under standard inductively coupled plasma (ICP) operating conditions (<3% cerium oxide ratio). At mass resolution (full width at half-maximum) M/DeltaM > 900 for m/z = 159, the sensitivity with a standard sample introduction system of >1.4 x 10(8) ion counts per second per mg L(-1) of Tb and an abundance sensitivity of (6 x 10(-4))-(1.4 x 10(-3)) (trailing and leading masses, respectively) are shown. The mass range (m/z = 125-215) and abundance sensitivity are sufficient for elemental immunoassay with up to 60 distinct available elemental tags. When <15 elemental tags are used, a higher sensitivity mode at lower resolution (M/DeltaM > 500) can be used, which provides >2.4 x 10(8) cps per mg L(-1) of Tb, at (1.5 x 10(-3))-(5.0 x 10(-3)) abundance sensitivity. The real-time simultaneous detection of multiple isotopes from individual 1.8 microm polystyrene beads labeled with lanthanides is shown. A real time single cell 20 antigen expression assay of model cell lines and leukemia patient samples immuno-labeled with lanthanide-tagged antibodies is presented.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19601617     DOI: 10.1021/ac901049w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  383 in total

1.  Single-cell mass cytometry of TCR signaling: amplification of small initial differences results in low ERK activation in NOD mice.

Authors:  Michael Mingueneau; Smita Krishnaswamy; Matthew H Spitzer; Sean C Bendall; Erica L Stone; Stephen M Hedrick; Dana Pe'er; Diane Mathis; Garry P Nolan; Christophe Benoist
Journal:  Proc Natl Acad Sci U S A       Date:  2014-10-31       Impact factor: 11.205

Review 2.  New technologies for autoimmune disease monitoring.

Authors:  Holden T Maecker; Garry P Nolan; Charles G Fathman
Journal:  Curr Opin Endocrinol Diabetes Obes       Date:  2010-08       Impact factor: 3.243

Review 3.  Selected reaction monitoring-based proteomics: workflows, potential, pitfalls and future directions.

Authors:  Paola Picotti; Ruedi Aebersold
Journal:  Nat Methods       Date:  2012-05-30       Impact factor: 28.547

Review 4.  Single cell analysis: the new frontier in 'omics'.

Authors:  Daojing Wang; Steven Bodovitz
Journal:  Trends Biotechnol       Date:  2010-04-29       Impact factor: 19.536

Review 5.  Systems biology in immunology: a computational modeling perspective.

Authors:  Ronald N Germain; Martin Meier-Schellersheim; Aleksandra Nita-Lazar; Iain D C Fraser
Journal:  Annu Rev Immunol       Date:  2011       Impact factor: 28.527

Review 6.  Systems immunogenetics of vaccines.

Authors:  Michael Mooney; Shannon McWeeney; Rafick-Pierre Sékaly
Journal:  Semin Immunol       Date:  2013-07-22       Impact factor: 11.130

Review 7.  New tools for classification and monitoring of autoimmune diseases.

Authors:  Holden T Maecker; Tamsin M Lindstrom; William H Robinson; Paul J Utz; Matthew Hale; Scott D Boyd; Shai S Shen-Orr; C Garrison Fathman
Journal:  Nat Rev Rheumatol       Date:  2012-05-31       Impact factor: 20.543

8.  Multiplexed ion beam imaging of human breast tumors.

Authors:  Michael Angelo; Sean C Bendall; Rachel Finck; Matthew B Hale; Chuck Hitzman; Alexander D Borowsky; Richard M Levenson; John B Lowe; Scot D Liu; Shuchun Zhao; Yasodha Natkunam; Garry P Nolan
Journal:  Nat Med       Date:  2014-03-02       Impact factor: 53.440

Review 9.  Single cell protein analysis for systems biology.

Authors:  Ezra Levy; Nikolai Slavov
Journal:  Essays Biochem       Date:  2018-10-26       Impact factor: 8.000

10.  Standardization and quality control for high-dimensional mass cytometry studies of human samples.

Authors:  Katja Kleinsteuber; Björn Corleis; Narges Rashidi; Nzuekoh Nchinda; Antonella Lisanti; Josalyn L Cho; Benjamin D Medoff; Douglas Kwon; Bruce D Walker
Journal:  Cytometry A       Date:  2016-08-30       Impact factor: 4.355

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.