"Hybrid" total knee arthroplasty with the Miller-Galante prosthesis. A prospective clinical and roentgenographic evaluation.

M J Kraay1, S A Meyers, V M Goldberg, H E Figgie, P A Conroy.   

Abstract

Twenty-nine "hybrid" Miller-Galante total knee arthroplasties, in 22 patients, were evaluated prospectively and according to the clinical and roentgenographic guidelines of The Knee Society. Selection of this technique, incorporating an uncemented, porous-ingrowth femoral component and a cemented tibial component, was based on patient age, medical condition, activity level, and intraoperative assessment of bone quality and ligament competency. The average age of the patients at the time of surgery was 71 years. The average preoperative Knee Society Knee Score was 32; average pain score was 14; and the average function score, 47. After an average follow-up interval of 28 months postsurgery (minimum, 24 months), the average Knee Society Knee Score was 93; the average pain score, 47; and the average function score, 79. Range of motion averaged 110 degrees. Only one knee, with persistent pain of obscure origin, rated an unsuccessful result. No arthroplasties were revised for any reason. Twenty-three knees had fluoroscopically guided roentgenograms to assess the bone-prosthesis and bone-cement interfaces. No significant or progressive radiolucencies were noted under any of the components. No apparent adverse bone remodeling was associated with the uncemented femoral component. The fluoroscopically guided roentgenograms were significantly more sensitive in detecting interface radiolucencies than plain ones. Clinical and roentgenographic evidence of component loosening were absent in all patients. Results of this study suggest that the hybrid fixation technique can reliably provide satisfactory pain relief and restoration of function in properly selected patients. Potential advantages of an uncemented femoral component include decreased operative time, reduction of polyethylene wear from cement debris, and avoidance of a possible adverse biologic response to polymethylmethacrylate.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1959284

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  7 in total

1.  Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup.

Authors:  Philip M Faris; E Michael Keating; Alex Farris; John B Meding; Merrill A Ritter
Journal:  Clin Orthop Relat Res       Date:  2008-03-07       Impact factor: 4.176

2.  Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh: a randomized clinical RSA study on cementless tibial components.

Authors:  Maiken Stilling; Frank Madsen; Anders Odgaard; Lone Rømer; Niels Trolle Andersen; Ole Rahbek; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

3.  Long-term Results of Hybrid Total Knee Arthroplasty: Minimum 10-years Follow-up.

Authors:  Young Joon Choi; Ki Won Lee; Chung Hwan Kim; Hyung Sun Ahn; Jae Kwang Hwang; Jeong Ho Kang; Hee Don Han; Wan Jong Cho; Jun Seok Park
Journal:  Knee Surg Relat Res       Date:  2012-05-31

4.  The effect of surgeon's preference for hybrid or cemented fixation on the long-term survivorship of total knee replacement.

Authors:  Christopher J Vertullo; Stephen E Graves; Yi Peng; Peter L Lewis
Journal:  Acta Orthop       Date:  2018-03-12       Impact factor: 3.717

5.  Results of Total Knee Arthroplasty with NexGen LPS-flex Implant Using Navigation System (Brain Lab): Results with a 5-year Follow-up.

Authors:  Chul Hyung Kang; Kyung Jae Lee; Ki Cheor Bae; Chul Hyun Cho; Si Wook Lee; Hong Kwan Shin; Young Kook Lee; Ji Suk Bae
Journal:  Knee Surg Relat Res       Date:  2012-11-29

6.  Hybrid total knee arthroplasty revisited: midterm followup of hybrid versus cemented fixation in total knee arthroplasty.

Authors:  Christopher E Pelt; Jeremy M Gililland; Justin Doble; Benjamin M Stronach; Christopher L Peters
Journal:  Biomed Res Int       Date:  2013-09-25       Impact factor: 3.411

7.  Clinical and radiological results of cruciate-retaining total knee arthroplasty with the NexGen®-CR system: comparison of patellar resurfacing versus retention with more than 14 years of follow-up.

Authors:  Keun Churl Chun; Sung Hyun Lee; Jong Seok Baik; Seng Hwan Kook; Joung Kyue Han; Churl Hong Chun
Journal:  J Orthop Surg Res       Date:  2017-10-02       Impact factor: 2.359

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.