Literature DB >> 19592107

Endothelial keratoplasty: the use of viscoelastic as an aid in reattaching the dislocated graft in abnormally structured eyes.

Rong-Mei Peng1, Yan-Sheng Hao, Hui-Jin Chen, Yan-Xiu Sun, Jing Hong.   

Abstract

PURPOSE: To explore the feasibility of reattaching the dislocated graft with viscoelastic in abnormally structured eyes after Descemet-stripping automated endothelial keratoplasty (DSAEK).
DESIGN: Retrospective case series. PARTICIPANTS: Five pseudophakic bullous keratopathy cases (5 eyes) with a history of vitrectomy and/or iris-lens diaphragm injury.
METHODS: After DSAEK, graft dislocation occurred in each of the 5 cases (5 eyes). We attempted to fill the anterior chamber (AC) with an air bubble to push up the dislocated graft, but this was not successful. We then injected balanced salt solution into the vitreous body to obtain normal intraocular pressure (IOP) and injected a small amount of viscoelastic (Healon GV) to support the AC. Next, we injected an air bubble into the AC. MAIN OUTCOME MEASURES: The position of the grafts was checked with a slit lamp and anterior segment optical coherence tomography (AS-OCT). The IOP was observed with Goldmann tonometer. The best visual acuity was checked.
RESULTS: As observed through the slit lamp and AS-OCT, the grafts reattached well in all patients. The IOP was normal in all patients except one, who had high IOP 1 month postoperatively. After receiving drug treatment, the patient's IOP returned to normal. The grafts had slight edema on postoperative day 1, but became transparent between days 5 and 8.
CONCLUSIONS: Viscoelastic aided in the reattachment of the dislocated graft in eyes with a history of vitrectomy and/or iris-lens diaphragm injury. The presence of viscoelastic in the AC in the early period of post-DSAEK was well tolerated in this small series.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19592107     DOI: 10.1016/j.ophtha.2009.03.049

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Complications and outcomes of descemet stripping automated endothelial keratoplasty with artisan aphakia intraocular lens implantation.

Authors:  Rong-Mei Peng; Yu-Xin Guo; Yuan Qiu; Yan-Sheng Hao; Jing Hong
Journal:  Int J Ophthalmol       Date:  2018-04-18       Impact factor: 1.779

2.  Application of sodium hyaluronate to the operation of suturing the corneal perforation.

Authors:  Tao Jiang; Jing Jiang; Yang Zhou; Gui-Qiu Zhao; Shan-Shan Yang; Hui Li; Li Shen
Journal:  Int J Ophthalmol       Date:  2010-09-18       Impact factor: 1.779

3.  Descemet's stripping automated endothelial keratoplasty in abnormal anterior segment: scleral indentation technique to enhance donor adherence.

Authors:  Chun-Chi Chiang; Jane-Ming Lin; Yi-Yu Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-01-29       Impact factor: 3.117

4.  Clinical outcome of Descemet stripping automated endothelial keratoplasty in 18 cases with iridocorneal endothelial syndrome.

Authors:  M Ao; Y Feng; G Xiao; Y Xu; J Hong
Journal:  Eye (Lond)       Date:  2017-12-15       Impact factor: 3.775

5.  Endothelial corneal transplants: indications, clinical profile and surgical outcomes in a tertiary care hospital.

Authors:  Vijay Kumar Sharma; Santosh Kumar; Sagarika Patyal; Hemant S Trehan; Arun Kumar Yadav; K Raji; Anirudh Singh
Journal:  Med J Armed Forces India       Date:  2019-04-15

6.  Ophthalmic transplantology: anterior segment of the eye - part I.

Authors:  Małgorzata Nita; Barbara Strzałka-Mrozik; Andrzej Grzybowski; Wanda Romaniuk; Urszula Mazurek
Journal:  Med Sci Monit       Date:  2012-05

Review 7.  Descemet stripping automated endothelial keratoplasty.

Authors:  Namrata Sharma; Prafulla K Maharana; Shipra Singhi; Neelima Aron; Mukesh Patil
Journal:  Indian J Ophthalmol       Date:  2017-03       Impact factor: 1.848

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.