Literature DB >> 19583762

Marginal accuracy of four-unit zirconia fixed dental prostheses fabricated using different computer-aided design/computer-aided manufacturing systems.

Philipp Kohorst1, Henrike Brinkmann, Jiang Li, Lothar Borchers, Meike Stiesch.   

Abstract

Besides load-bearing capacity, marginal accuracy is a further crucial factor influencing the clinical long-term reliability of fixed dental prostheses (FDPs). The aim of this in vitro study was to evaluate the marginal fit of four-unit zirconia bridge frameworks fabricated using four different computer-aided design (CAD)/computer-aided manufacturing (CAM) systems. Ten frameworks were manufactured using each fabricating system. Three systems (inLab, Everest, Cercon) processed white-stage zirconia blanks, which had to be sintered to final density after milling, while with one system (Digident) restorations were directly milled from a fully sintered material. After manufacturing, horizontal and vertical marginal discrepancies, as well as the absolute marginal discrepancy, were determined by means of a replica technique. The absolute marginal discrepancy, which is considered to be the most suitable parameter reflecting restorations' misfit in the marginal area, had a mean value of 58 mum for the Digident system. By contrast, mean absolute marginal discrepancies for the three other systems, processing presintered blanks, differed significantly and ranged between 183 and 206 mum. Within the limitations of this study, it could be concluded that the marginal fit of zirconia FDPs is significantly dependent on the CAD/CAM system used, with restorations processed of fully sintered zirconia showing better fitting accuracy.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19583762     DOI: 10.1111/j.1600-0722.2009.00622.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  31 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  Influence of conventional and digital intraoral impressions on the fit of CAD/CAM-fabricated all-ceramic crowns.

Authors:  S Berrendero; M P Salido; A Valverde; A Ferreiroa; G Pradíes
Journal:  Clin Oral Investig       Date:  2016-01-23       Impact factor: 3.573

3.  Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques.

Authors:  Júnio S Almeida e Silva; Kurt Erdelt; Daniel Edelhoff; Élito Araújo; Michael Stimmelmayr; Luiz Clovis Cardoso Vieira; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2013-05-29       Impact factor: 3.573

4.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

5.  Prosthetic misfit of implant-supported prosthesis obtained by an alternative section method.

Authors:  Rodrigo Tiossi; Hilmo Barreto Leite Falcão-Filho; Fábio Afrânio de Aguiar; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

6.  Trueness of four different milling procedures used in dental CAD/CAM systems.

Authors:  Corinna Kirsch; Andreas Ender; Thomas Attin; Albert Mehl
Journal:  Clin Oral Investig       Date:  2016-07-28       Impact factor: 3.573

7.  Fit of 4-unit FDPs from CoCr and zirconia after conventional and digital impressions.

Authors:  Kazuhiko Ueda; Florian Beuer; Michael Stimmelmayr; Kurt Erdelt; Christine Keul; Jan-Frederik Güth
Journal:  Clin Oral Investig       Date:  2015-06-30       Impact factor: 3.573

8.  Evaluating the effect of repeated use of milling burs on surface roughness and adaptation of digitally fabricated ceramic veneers.

Authors:  Leila Payaminia; Naeime Moslemian; Shima Younespour; Soudabeh Koulivand; Marzieh Alikhasi
Journal:  Heliyon       Date:  2021-04-30

9.  Clinical performance and failures of zirconia-based fixed partial dentures: a review literature.

Authors:  Premwara Triwatana; Noppavan Nagaviroj; Chantana Tulapornchai
Journal:  J Adv Prosthodont       Date:  2012-05-30       Impact factor: 1.904

10.  Rapid tooling method for soft customized removable oral appliances.

Authors:  Mika Salmi; Jukka Tuomi; Rauno Sirkkanen; Tuula Ingman; Antti Mäkitie
Journal:  Open Dent J       Date:  2012-05-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.