Overcoming electromagnetic interference by LVADs on ICD function by shielding the ICD programmer wand and extension cable.

Angelo Biviano1, Donna Mancini, Yoshifumi Naka, Jerry Arellano, Hasan Garan.   

Abstract

Patients with end-stage cardiomyopathy and congestive heart failure are increasingly undergoing implantation with left ventricular assist devices (LVADs). In addition, implantable cardioverter-defibrillator (ICD) therapy has been proven to be an important part of the treatment for cardiomyopathy/congestive heart failure. Previous reports have noted a potential and dramatic electromagnetic interference from LVADs on ICDs that cause impaired telemetry communication between the ICD and ICD programmer. Such interference has necessitated explantation and generator replacement in order to resume communication between the ICD and programmer. We report two patients with advanced congestive heart failure and ICD programming impairment caused by a HeartMate II LVAD (Thoratec Corporation, Pleasanton, CA, USA) that was overcome by placing aluminum shielding around the ICD programmer wand and steel shielding around the extension cable during ICD interrogation.

Entities:  

Mesh:

Year:  2009        PMID: 19572875     DOI: 10.1111/j.1540-8159.2009.02419.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  3 in total

1.  Clinical implications of left ventricular assist device implantation in patients with an implantable cardioverter-defibrillator.

Authors:  Fanny Boudghène-Stambouli; Stéphane Boulé; Céline Goéminne; Edward Botcherby; Christelle Marquié; Claude Kouakam; Laurence Guédon-Moreau; Guillaume Schurtz; Pascal de Groote; Nicolas Lamblin; Marie Fertin; Emmanuel Robin; François Brigadeau; Didier Klug; Dominique Lacroix; Jonathan Meurice; Ludivine Wissocque; André Vincentelli; Salem Kacet
Journal:  J Interv Card Electrophysiol       Date:  2013-12-13       Impact factor: 1.900

Review 2.  Electromagnetic interference between implantable cardiac devices and continuous-flow left ventricular assist devices: a review.

Authors:  Jonathan S Gordon; Elizabeth J Maynes; Thomas J O'Malley; Behzad B Pavri; Vakhtang Tchantchaleishvili
Journal:  J Interv Card Electrophysiol       Date:  2021-01-12       Impact factor: 1.900

Review 3.  Electric smog: telemetry interference between ICD and LVAD.

Authors:  David Duncker; Thorben König; Johanna Müller-Leisse; Roman Michalski; Hanno Oswald; Jan D Schmitto; Johann Bauersachs; Christian Veltmann
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2017-05-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.