Literature DB >> 19568186

Biomechanics studies in dentistry: bioengineering applied in oral implantology.

Wirley Gonçalves Assunção1, Valentim Adelino Ricardo Barão, Lucas Fernando Tabata, Erica Alves Gomes, Juliana Aparecida Delben, Paulo Henrique dos Santos.   

Abstract

The application of engineering knowledge in dentistry has helped the understanding of biomechanics aspects related to osseointegrated implants. Several techniques have been used to evaluate the biomechanical load on implants comprising the use of photoelastic stress analysis, finite element stress analysis, and strain-gauge analysis. Therefore, the purpose of this study was to describe engineering methods used in dentistry to evaluate the biomechanical behavior of osseointegrated implants. Photoelasticity provides good qualitative information on the overall location and concentration of stresses but produces limited quantitative information. The method serves as an important tool for determining the critical stress points in a material and is often used for determining stress concentration factors in irregular geometries. The application of strain-gauge method on dental implants is based on the use of electrical resistance strain gauges and its associated equipment and provides both in vitro and vivo measurements strains under static and dynamic loads. However, strain-gauge method provides only the data regarding strain at the gauge. Finite element analysis can simulate stress using a computer-created model to calculate stress, strain, and displacement. Such analysis has the advantage of allowing several conditions to be changed easily and allows measurement of stress distribution around implants at optional points that are difficult to examine clinically. All the 3 methodologies can be useful to evaluate biomechanical implant behavior close to the clinical condition but the researcher should have enough knowledge in model fabrication (experimental delineation) and results analysis.

Mesh:

Substances:

Year:  2009        PMID: 19568186     DOI: 10.1097/SCS.0b013e3181acdb81

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  7 in total

1.  Influence of implant number, length, and tilting degree on stress distribution in atrophic maxilla: a finite element study.

Authors:  Zeynep Gümrükçü; Yavuz Tolga Korkmaz
Journal:  Med Biol Eng Comput       Date:  2017-11-09       Impact factor: 2.602

2.  Influence of Occlusal Bite Forces on Teeth with Altered Periodontal Support: A Three-Dimensional Finite Element Stress Analysis.

Authors:  Richa Agrawal; Sumit Narang; Hina Ahmed; Shyam Prasad; Shyamsunder Reddy; Shivaramakrishna Aila
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

3.  Biomechanical Stress in Obturator Prostheses: A Systematic Review of Finite Element Studies.

Authors:  Mohammed A Mousa; Johari Yap Abdullah; Nafij B Jamayet; Mohammad Khursheed Alam; Adam Husein
Journal:  Biomed Res Int       Date:  2021-08-16       Impact factor: 3.411

4.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

5.  Influence of Implant Design (Cylindrical and Conical) in the Load Transfer Surrounding Long (13mm) and Short (7mm) Length Implants: A Photoelastic Analysis.

Authors:  Sergio Alexandre Gehrke; Victor Lourenço Frugis; Jamil Awad Shibli; Maria Piedad Ramirez Fernandez; José Eduardo Maté Sánchez de Val; José Luis Calvo Girardo; Silvio Taschieri; Stefano Corbella
Journal:  Open Dent J       Date:  2016-09-30

6.  Evaluation of strain in mandibular denture-supporting area in three different occlusal schemes during jaw movements.

Authors:  Ali Hafezeqoran; Roodabeh Koodaryan; Seyed Gholamreza Noorazar; Masoud Hajialilue-Bonab; Mehran Hassanzadeh; Neda Yasamineh
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2018-03-14

7.  Importance of a distal proximal contact on load transfer by implant-supported single adjacent crowns in posterior region of the mandible: a photoelastic study.

Authors:  Fábio Afrânio de Aguiar Júnior; Rodrigo Tiossi; Ana Paula Macedo; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro; Renata Cristina Silveira Rodrigues
Journal:  J Appl Oral Sci       Date:  2013 Sep-Oct       Impact factor: 2.698

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.