Absorption measurements on a new cone beam CT and IMRT compatible tabletop for use in external radiotherapy.

M Berg1, J P Bangsgaard, I S Vogelius.   

Abstract

With the development of intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy (IMAT), volumetric single arc therapy (RapidArc) and cone beam CT (CBCT) in 3D conformal radiotherapy, a need for new homogeneous treatment tabletops has evolved. Therefore, a new homogenous carbon fibre rotatable treatment tabletop Contesse has been developed. The intension was to create a CT compatible treatment tabletop accommodating all the standard treatment areas without add-on devises or the need to reconfigure the tabletop in everyday practice. At the same time, the absorption was sought to be minimized. Measurements of absorption with an ionization chamber have been performed for the main treatment geometries at normal and oblique angles together with build-up measurements at normal incidence. Absorption and build-up properties were shown to be comparable to those of other treatment tabletops with similar fixation devices. No artefacts from the tabletop are seen on CBCT scans. In order to reveal the absorption characteristics of tabletops, careful measurements at oblique angles including fixation devices on all clinically used tabletops must be performed. The Contesse tabletop is CBCT compatible, has acceptable absorption and is presently being used in the clinic for all patients, including IMRT and kilovoltage CBCT.

Entities:  

Mesh:

Year:  2009        PMID: 19567944     DOI: 10.1088/0031-9155/54/14/N04

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Correction for patient table-induced scattered radiation in cone-beam computed tomography (CBCT).

Authors:  Mingshan Sun; Tamás Nagy; Gary Virshup; Larry Partain; Markus Oelhafen; Josh Star-Lack
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

2.  Dosimetry Comparison between Volumetric Modulated Arc Therapy with Rapid Arcand Fixed Field Dynamic IMRT for Local-Regionally Advanced Nasopharyngeal Carcinoma.

Authors:  Bao-Min Zheng; Xiao-Xia Dong; Hao Wu; Shu-Kui Han; Yan Sun
Journal:  Chin J Cancer Res       Date:  2011-12       Impact factor: 5.087

3.  A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose.

Authors:  Christopher F Njeh; Jason Parker; Joseph Spurgin; Elizabeth Rhoe
Journal:  Radiat Oncol       Date:  2012-11-09       Impact factor: 3.481

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.