Literature DB >> 19567847

The Morscher Press Fit acetabular component: a nine- to 13-year review.

D P Gwynne-Jones1, N Garneti, C Wainwright, J A Matheson, R King.   

Abstract

We reviewed the results at nine to 13 years of 125 total hip replacements in 113 patients using the monoblock uncemented Morscher press-fit acetabular component. The mean age at the time of operation was 56.9 years (36 to 74). The mean clinical follow-up was 11 years (9.7 to 13.5) and the mean radiological follow-up was 9.4 years (7.7 to 13.1). Three hips were revised, one immediately for instability, one for excessive wear and one for deep infection. No revisions were required for aseptic loosening. A total of eight hips (7.0%) had osteolytic lesions greater than 1 cm, in four around the acetabular component (3.5%). One required bone grafting behind a well-fixed implant. The mean wear rate was 0.11 mm/year (0.06 to 0.78) and was significantly higher in components with a steeper abduction angle. Kaplan-Meier survival curves at 13 years showed survival of 96.8% (95% confidence interval 90.2 to 99.0) for revision for any cause and of 95.7% (95% confidence interval 88.6 to 98.4) for any acetabular re-operation.

Entities:  

Mesh:

Year:  2009        PMID: 19567847     DOI: 10.1302/0301-620X.91B7.22013

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  7 in total

Review 1.  Do monoblock cups improve survivorship, decrease wear, or reduce osteolysis in uncemented total hip arthroplasty?

Authors:  Jelle J Halma; H Charles Vogely; Wouter J Dhert; Steven M Van Gaalen; Arthur de Gast
Journal:  Clin Orthop Relat Res       Date:  2013-08-03       Impact factor: 4.176

Review 2.  Survival outcomes of cemented compared to uncemented stems in primary total hip replacement.

Authors:  Michael Wyatt; Gary Hooper; Christopher Frampton; Alastair Rothwell
Journal:  World J Orthop       Date:  2014-11-18

3.  Clinical faceoff: One- versus two-stage exchange arthroplasty for prosthetic joint infections.

Authors:  Montri D Wongworawat
Journal:  Clin Orthop Relat Res       Date:  2013-03-01       Impact factor: 4.176

4.  Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

Authors:  Guido Garavaglia; Anne Lübbeke; Christophe Barea; Constantinos Roussos; Robin Peter; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2010-06-04       Impact factor: 3.075

5.  Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Göran Garellick; Johan Kärrholm
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

6.  Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register.

Authors:  Rüdiger J Weiss; Nils P Hailer; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-05-10       Impact factor: 3.717

7.  A vitamin E blended highly cross-linked polyethylene acetabular cup results in less wear: 6-year results of a randomized controlled trial in 199 patients.

Authors:  Julie R A Massier; Joost H J Van Erp; Thom E Snijders; Arthur DE Gast
Journal:  Acta Orthop       Date:  2020-08-24       Impact factor: 3.717

  7 in total