The design of the Charnley total hip replacement follows the principle of low frictional torque. It is based on the largest possible difference between the radius of the femoral head and that of the outer aspect of the acetabular component. The aim is to protect the bone-cement interface by movement taking place at the smaller radius, the articulation. This is achieved in clinical practice by a 22.225 mm diameter head articulating with a 40 mm or 43 mm diameter acetabular component of ultra-high molecular weight polyethylene. We compared the incidence of aseptic loosening of acetabular components with an outer diameter of 40 mm and 43 mm at comparable depths of penetration with a mean follow-up of 17 years (1 to 40). In cases with no measurable wear none of the acetabular components were loose. With increasing acetabular penetration there was an increased incidence of aseptic loosening which reflected the difference in the external radii, with 1.5% at 1 mm, 8.8% at 2 mm, 9.7% at 3 mm and 9.6% at 4 mm of penetration in favour of the larger 43 mm acetabular component. Our findings support the Charnley principle of low frictional torque. The level of the benefit is in keeping with the predicted values.

Entities:  

Mesh:

Year:  2009        PMID: 19567846     DOI: 10.1302/0301-620X.91B7.22027

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  5 in total

1.  Understanding wear in dual mobility total hip replacement: first generation explant wear patterns.

Authors:  Bertrand Boyer; Thomas Neri; Jean Geringer; Alexandre Di Iorio; Remi Philippot; Frederic Farizon
Journal:  Int Orthop       Date:  2016-12-07       Impact factor: 3.075

Review 2.  Restoration of center of rotation and balance of THR.

Authors:  Zachary C Lum; Lawrence D Dorr
Journal:  J Orthop       Date:  2018-09-06

3.  Low failure rate at short term for 40 mm heads and second generation triple annealed HCLPE liners in hybrid hip replacements.

Authors:  Rajkumar Thangaraj; Jan Kuiper; Ralph D Perkins
Journal:  J Clin Orthop Trauma       Date:  2018-01-03

4.  The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up.

Authors:  Yama Afghanyar; Sebastian Joser; Jonas Tecle; Philipp Drees; Jens Dargel; Philipp Rehbein; Karl Philipp Kutzner
Journal:  BMC Musculoskelet Disord       Date:  2021-01-23       Impact factor: 2.362

5.  Neck fracture of the Exeter stem in 3 patients: A cause for concern?

Authors:  Aleksi Reito; Antti Eskelinen; Jorma Pajamäki; Timo Puolakka
Journal:  Acta Orthop       Date:  2015-11-06       Impact factor: 3.717

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.