Literature DB >> 19566357

Totally implantable subpectoral vs. subcutaneous port systems in children with malignant diseases.

Mohsen Rouzrokh1, Bibi Shahin Shamsian, Ahmad KhaleghNejad Tabari, Morteza Mahmoodi, Jafar Kouranlo, Gholamreza Manafzadeh, Mohammad Taghi Arzanian, Fateme Fallah, Mahdieh Anoush, Fatemeh Abdollah Gorji.   

Abstract

BACKGROUND: For many years, subcutaneous therapeutic port system was known as a major route to access central veins. However, significant complications have been reported through recent years. One of the most important complications of subcutaneous port implantation is skin necrosis. In order to decrease this complication, we would like to introduce subpectoral fascia port implantation through this study.
METHODS: Five hundred and twenty four patients with a variety of neoplastic diseases underwent port implantation, from March 2003 to March 2008 (60 months). All suitable size catheters were put in the superior vena cava through the internal jugular vein under general anesthesia. The ports were placed in the subcutaneous pocket (SCP group) in 342 patients and in the subpectoral fascia pocket (SPFP group) in 182 patients. Data were analyzed using Chi-square test and survival analysis for time (Kaplan-Meier).
RESULTS: A total of 538 devices were placed for 524 patients in two groups (14 patients received a second device after removal of the first one, due to failure of the first implantation). Mean follow-up period was 508 days (8 - 2025 days).Common complications observed in the SPFP group were as follows: wound infection (7 cases, 3.8%), catheter obstruction (7 cases, 3.8%), catheter displacement (6 cases, 3.2%), port related infection (5 cases, 2.7%), and pocket hematoma (2 cases, 1.1%).Common complications observed in the SCP group were as follows: catheter displacement (12 cases, 3.5%), skin necrosis (11 cases, 3.21%), port exposure (9 cases, 2.6%), port related infection (8 cases, 2.3%), catheter obstruction (8 cases, 2.3%), and port rotation (3 cases, 0.9%).
CONCLUSION: The results showed that port implantation in the subpectoral fascia pocket had a lower rate of skin complications than the subcutaneous pocket implantation. According to this study, this procedure was not complicated by skin necrosis over the port, port exposure or port rotation.

Entities:  

Mesh:

Year:  2009        PMID: 19566357

Source DB:  PubMed          Journal:  Arch Iran Med        ISSN: 1029-2977            Impact factor:   1.354


  5 in total

1.  Study of feasibility and acceptability of subcutaneous implantable ports (SIPs) in cancer patients.

Authors:  Lalit Mittal; Manas Kalra; Amita Mahajan
Journal:  Indian J Pediatr       Date:  2012-02-29       Impact factor: 1.967

2.  Central venous port systems as an integral part of chemotherapy.

Authors:  Ulf K Teichgräber; Robert Pfitzmann; Herbert A F Hofmann
Journal:  Dtsch Arztebl Int       Date:  2011-03-04       Impact factor: 5.594

Review 3.  Surgical placement of totally implantable venous access device-an institutional experience.

Authors:  Aravindan Chandrasekaran; Jayabose Somasundaram
Journal:  Indian J Pediatr       Date:  2013-08-14       Impact factor: 1.967

4.  [Catheters with implantable chamber: report of a series of 970 cases].

Authors:  El Hassane Kabiri; Massine El Hammoumi; Akram Traibi; Faycal El Oueriachi; Adil Arsalane
Journal:  Pan Afr Med J       Date:  2012-07-13

5.  Thrombosis as a complication of central venous access in pediatric patients with malignancies: a 5-year single-center experience.

Authors:  Verena Wiegering; Sophie Schmid; Oliver Andres; Clemens Wirth; Armin Wiegering; Thomas Meyer; Beate Winkler; Paul G Schlegel; Matthias Eyrich
Journal:  BMC Hematol       Date:  2014-10-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.