Bioabsorbable anchors in glenohumeral shoulder surgery.

Shane J Nho1, Matthew T Provencher, Shane T Seroyer, Anthony A Romeo.   

Abstract

The use of implants to provide glenohumeral soft tissue fixation has changed dramatically over the past few decades, from point tack fixation to metallic suture anchors to bioabsorbable suture anchors. Bioabsorbable suture anchors have largely replaced metallic anchors because of concerns of implant loosening, migration, and chondral injury. Although the safety and efficacy of bioabsorbable anchors has been well documented, there are numerous reports regarding the early failure related to implant bioabsorbable implant breakage or premature degradation. Patients with anchor-related complications generally present with pain and/or stiffness, and the surgeon should have a high index of suspicion if a patient does not progress as expected. Glenohumeral synovitis, glenoid osteolysis, loose bodies, and chondral injury are some of the notable complications that have been reported. Careful attention to proper anchor insertion techniques can limit the potential for complications. Newer materials, such as polyetheretherketone and other composites, have recently been introduced. These materials may address concerns of biocompatibility and material strength, but additional rigorous in vitro and in vivo trials need to be conducted before their use becomes widespread.

Entities:  

Mesh:

Year:  2009        PMID: 19560644     DOI: 10.1016/j.arthro.2008.08.018

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  24 in total

1.  Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

Authors:  Mohammad Reza Hayeri; Daniel T Keefe; Eric Y Chang
Journal:  Skeletal Radiol       Date:  2016-01-06       Impact factor: 2.199

2.  MRI assessment of the structural labrum integrity after Bankart repair using knotless bio-anchors.

Authors:  T Stein; A P Mehling; C Reck; J Buckup; T Efe; R Hoffmann; A Jäger; F Welsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-11       Impact factor: 4.342

3.  Glenoid rim fracture through anchor points after arthroscopic Bankart repair for shoulder instability.

Authors:  Jin-Young Park; Seung-Jun Lee; Se-Kwan Oh; KyungSoo Oh; YoungMin Noh; Kuen-Tak Suh
Journal:  Int Orthop       Date:  2014-11-29       Impact factor: 3.075

4.  MRI graduation of osseous reaction and drill hole consolidation after arthroscopic Bankart repair with PLLA anchors and the clinical relevance.

Authors:  T Stein; A P Mehling; M Ulmer; C Reck; T Efe; R Hoffmann; A Jäger; F Welsch
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-02       Impact factor: 4.342

5.  Biocomposite Suture Anchors Remain Visible Two Years After Rotator Cuff Repair.

Authors:  Mirco Sgroi; Theresa Friesz; Michael Schocke; Heiko Reichel; Thomas Kappe
Journal:  Clin Orthop Relat Res       Date:  2019-06       Impact factor: 4.176

6.  Comparison between all-suture and biocomposite anchors in the arthroscopic treatment of traumatic anterior shoulder instability: A retrospective cohort study.

Authors:  Ioannis Pantekidis; Michael-Alexander Malahias; Stefania Kokkineli; Emmanouil Brilakis; Emmanouil Antonogiannakis
Journal:  J Orthop       Date:  2021-03-27

7.  Does the Anchor Eye Alignment Affect the Performance of the Rotator Cuff Repair? A Biomechanical Study.

Authors:  Lara Locatelli; Cesar A Q Martins; Arthur P G Santos; Patricia O Cubillos; Carlos R M Roesler
Journal:  Arthrosc Sports Med Rehabil       Date:  2021-02-01

8.  Analysis of the functional results of arthroscopic Bankart repair in posttraumatic recurrent anterior dislocations of shoulder.

Authors:  Amit Mishra; Pulak Sharma; Deepak Chaudhary
Journal:  Indian J Orthop       Date:  2012-11       Impact factor: 1.251

9.  Bony Versus Soft Tissue Reconstruction for Anterior Shoulder Instability: An Expected Value Decision Analysis.

Authors:  Richard James McLaughlin; Anthony Miniaci; Morgan H Jones
Journal:  Orthop J Sports Med       Date:  2015-12-16

10.  Anterior Glenoid Rim Fracture Following Use of Resorbable Devices for Glenohumeral Stabilization.

Authors:  Carlo Alberto Augusti; Paolo Paladini; Fabrizio Campi; Giovanni Merolla; Marco Bigoni; Giuseppe Porcellini
Journal:  Orthop J Sports Med       Date:  2015-06-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.