Literature DB >> 19551508

A simulation of vessel-clamp interaction: transient closure dynamics.

Henry Y Chen1, Jose A Navia, Ghassan S Kassab.   

Abstract

Cross-clamping of aorta is routinely performed in cardiac surgery. The objective of this study was to simulate cross-clamping of the aorta to elucidate the perturbation of stresses in the wall (solid mechanics) and lumen of the vessel (fluid mechanics). Models of the aorta and clamp were created in Computer Assisted Design and Finite Element Analysis packages. The vessel wall was considered as a non-linear anisotropic material while the fluid was simulated as Newtonian with pulsatile flow. The clamp was applied to produce total occlusion in approximately 1 s. A cylindrical and rectangular geometry for the clamp were considered. High jet speed and flow reversal were demonstrated during clamping. It was found that the clamp design and vessel wall anisotropy affected both the fluid wall shear stress (WSS) and solid stresses in vessel wall. The maximum wall stresses increased by about 170 and 220% during closure in the cases of plate and cylindrical clamps, respectively. The plate clamp design was superior for reduction of both solid stresses as well as fluid shear stresses. The cylindrical clamp causes much larger stresses than the plate clamp in each of the stress components; e.g., radial compression of -180 vs. -50 kPa. Vibrations, flow and WSS oscillations were detected immediately before total vessel occlusion. The present findings provide valuable insights into the mode of tissue injury during clamping and may also be useful for improving surgical clamp designs.

Entities:  

Mesh:

Year:  2009        PMID: 19551508      PMCID: PMC3238100          DOI: 10.1007/s10439-009-9748-4

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  16 in total

1.  A three-dimensional finite element model for arterial clamping.

Authors:  Thomas C Gasser; Christian A J Schulze-Bauer; Gerhard A Holzapfel
Journal:  J Biomech Eng       Date:  2002-08       Impact factor: 2.097

2.  Fluid-induced shear stress stimulates chondrocyte proliferation partially mediated via TGF-beta1.

Authors:  Prasanna Malaviya; Robert M Nerem
Journal:  Tissue Eng       Date:  2002-08

3.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

4.  Nitric oxide is significantly reduced in ex vivo porcine arteries during reverse flow because of increased superoxide production.

Authors:  X Lu; G S Kassab
Journal:  J Physiol       Date:  2004-10-07       Impact factor: 5.182

5.  Proper orientation of the graft artery is important to ensure physiological flow direction.

Authors:  Ghassan S Kassab; Jose A Navia; Xiao Lu
Journal:  Ann Biomed Eng       Date:  2006-05-24       Impact factor: 3.934

Review 6.  Biomechanics of the cardiovascular system: the aorta as an illustratory example.

Authors:  Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2006-12-22       Impact factor: 4.118

7.  Endothelial mechanisms of flow-mediated athero-protection and susceptibility.

Authors:  Peter F Davies
Journal:  Circ Res       Date:  2007-07-06       Impact factor: 17.367

8.  Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflation.

Authors:  Y Okazaki; K Takarabe; J Murayama; E Suenaga; K Furukawa; K Rikitake; M Natsuaki; T Itoh
Journal:  Eur J Cardiothorac Surg       Date:  2001-06       Impact factor: 4.191

9.  Effect of surrounding tissue on vessel fluid and solid mechanics.

Authors:  Wei Zhang; Carly Herrera; Satya N Atluri; Ghassan S Kassab
Journal:  J Biomech Eng       Date:  2004-12       Impact factor: 2.097

10.  Extra-anatomic coronary artery bypass graftings in patients with porcelain aorta.

Authors:  E Demirsoy; M Unal; H Arbatli; N Yagan; F Tukenmez; B Sonmez
Journal:  J Cardiovasc Surg (Torino)       Date:  2004-04       Impact factor: 1.888

View more
  2 in total

1.  Mis-sizing of stent promotes intimal hyperplasia: impact of endothelial shear and intramural stress.

Authors:  Henry Y Chen; Anjan K Sinha; Jenny S Choy; Hai Zheng; Michael Sturek; Brian Bigelow; Deepak L Bhatt; Ghassan S Kassab
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-09-16       Impact factor: 4.733

2.  Can the arterial clamp method be used safely where a tourniquet cannot be used?

Authors:  Ozgur Erdogan; Volkan Gürkan; Cavide Sönmez; Tunay Erden; Sezen Atasoy; Fatih Yildiz; Bekir İnan; Adile Adilli
Journal:  Cardiovasc J Afr       Date:  2021-07-07       Impact factor: 1.167

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.