Literature DB >> 16783651

Proper orientation of the graft artery is important to ensure physiological flow direction.

Ghassan S Kassab1, Jose A Navia, Xiao Lu.   

Abstract

Arterial grafts such as right internal mammary artery (RIMA), radial artery (RA) or epigastric artery are being used with increasing frequency as free grafts or as composite grafts with left internal mammary artery (LIMA). Currently, there is no consideration of the orientation of the free artery graft to mimic the in vivo state. Hence, some grafts may be oriented such that the direction of blood flow exerted on the endothelium is reversed relative to the in vivo condition. Previous studies have shown that transient flow reversal lead to atherogenesis. A recent study demonstrated that nitric oxide is significantly reduced during reverse flow and the reduction is mediated through an increase in superoxide production. In light of these data, we suggest that the flow direction is important and recommend the assurance of proper orientation of the free arterial graft. Furthermore, we propose a new surgical procedure to modify the composite LIMA-RA or LIMA-RIMA configuration as a horseshoe or K composite graft to ensure proper orientation of the flow direction relative to the endothelium.

Entities:  

Mesh:

Year:  2006        PMID: 16783651     DOI: 10.1007/s10439-006-9104-x

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  6 in total

1.  Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Deepak L Bhatt; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2013-05-30

2.  Impact of bifurcation dual stenting on endothelial shear stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2015-07-16

3.  Impact of main branch stenting on endothelial shear stress: role of side branch diameter, angle and lesion.

Authors:  Henry Y Chen; Issam D Moussa; Charles Davidson; Ghassan S Kassab
Journal:  J R Soc Interface       Date:  2011-11-23       Impact factor: 4.118

4.  Fluid-structure interaction in aortic cross-clamping: implications for vessel injury.

Authors:  Henry Y Chen; Jose A Navia; Shoaib Shafique; Ghassan S Kassab
Journal:  J Biomech       Date:  2009-11-01       Impact factor: 2.712

5.  Distinctive subcellular Akt-1 responses to shear stress in endothelial cells.

Authors:  Benoît Melchior; John A Frangos
Journal:  J Cell Biochem       Date:  2014-01       Impact factor: 4.429

6.  A simulation of vessel-clamp interaction: transient closure dynamics.

Authors:  Henry Y Chen; Jose A Navia; Ghassan S Kassab
Journal:  Ann Biomed Eng       Date:  2009-06-24       Impact factor: 3.934

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.