BACKGROUND: Concerns about the Gamma nail have largely been fueled by early randomized trials and meta-analyses suggesting an increased risk of subsequent femoral shaft fractures when compared with compression hip screws. Whereas meta-analyses favor compression hip screws over first-generation Gamma nails, little is known as to whether the newer Gamma nail designs and the improved learning curve associated with the implants have reduced the risk of femoral shaft fracture. The current meta-analysis aimed to explore the effects of time and Gamma Nail design on the risks of femoral shaft fracture after treatment of extracapsular hip fractures.
METHODS: We searched computerized databases (Medline, Cochrane, and SciSearch) for published randomized clinical trials from 1969 to 2002, and we identified additional studies through hand searches of major orthopedic journals, bibliographies of major orthopedic texts, and personal files. Two investigators independently graded study quality and abstracted relevant data. We abstracted information on subsequent femoral shaft fracture rates from studies. We pooled data using a random-effects model and tested for heterogeneity using the I test. We conducted sensitivity analyses by date and by generation of the Gamma nail. We further conducted a cumulative meta-analysis to explore the treatment effect over time.
RESULTS: We identified 25 relevant randomized trials from 1991 to 2005. In earlier studies (N = 1585 patients), Gamma nails increased the risk of femoral shaft fracture 4.5 times compared with a compression hip screw (95% confidence interval: 1.78-11.36, P = 0.0014, I(2) = 0%). However, among the most recent studies (2000-2005), Gamma nails did not significantly increase femoral shaft fracture risk (relative risk = 1.65, 95% confidence interval: 0.50-5.44, P = 0.41, I(2) = 0%). The most recent study (2005) found no difference in femoral fracture rates (relative risk = 1.03, 95% confidence interval = 0.06-16.2, P = 0.99).
CONCLUSIONS: Our meta-analysis of randomized trials suggests that previous concerns about increased femoral shaft fracture risk with Gamma nails have been resolved with improved implant design and improved learning curves with the device. Earlier meta-analyses and randomized trials should be interpreted with caution in light of more recent evidence.

Entities:  

Mesh:

Year:  2009        PMID: 19550235     DOI: 10.1097/BOT.0b013e318162f67f

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  51 in total

1.  Comparative study of InterTAN and Dynamic Hip Screw in treatment of femoral intertrochanteric injury and wound.

Authors:  Qiang Wang; Xin Yang; Hua-Zheng He; Li-Jun Dong; De-Gang Huang
Journal:  Int J Clin Exp Med       Date:  2014-12-15

2.  Intertrochanteric Fracture of the Femur in an Ankylosed Hip: A Case Report.

Authors:  Pramod Devkota; Shiraz Ahmad; Ketan C Pande
Journal:  Rev Bras Ortop (Sao Paulo)       Date:  2019-10-09

Review 3.  Fractures in brief: intertrochanteric hip fractures.

Authors:  Jaimo Ahn; Joseph Bernstein
Journal:  Clin Orthop Relat Res       Date:  2010-05       Impact factor: 4.176

Review 4.  Cochrane in CORR ®: Intramedullary nails for extracapsular hip fractures in adults (review).

Authors:  Nathan Evaniew; Mohit Bhandari
Journal:  Clin Orthop Relat Res       Date:  2015-01-06       Impact factor: 4.176

5.  Biomechanical evaluation of the risk of secondary fracture around short versus long cephalomedullary nails.

Authors:  William E Daner; John R Owen; Jennifer S Wayne; Ryan B Graves; Mark C Willis
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-06-08

6.  Convergence of outcomes for hip fracture fixation by nails and plates.

Authors:  Foster Chen; Zhong Wang; Timothy Bhattacharyya
Journal:  Clin Orthop Relat Res       Date:  2012-11-27       Impact factor: 4.176

Review 7.  Is rotation the mode of failure in pertrochanteric fractures fixed with nails? Theoretical approach and illustrative cases.

Authors:  C Kokoroghiannis; D Vasilakos; K Zisis; G Dimitriou; E Pappa; D Evangelopoulos
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-09-20

8.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

Review 9.  Intertrochanteric fractures: a review of fixation methods.

Authors:  Senthil Nathan Sambandam; Jayadev Chandrasekharan; Varatharaj Mounasamy; Cyril Mauffrey
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-03-30

10.  CORR Insights™: Intramedullary nails result in more reoperations than sliding hip screws in two-part intertrochanteric fractures.

Authors:  Paul J Dougherty
Journal:  Clin Orthop Relat Res       Date:  2013-04       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.