Literature DB >> 19546430

Measurement of hepatic lipid: high-speed T2-corrected multiecho acquisition at 1H MR spectroscopy--a rapid and accurate technique.

Nashiely Pineda1, Puneet Sharma, Qin Xu, Xiaoping Hu, Miriam Vos, Diego R Martin.   

Abstract

PURPOSE: To evaluate the feasibility, accuracy, and reproducibility of a fast breath-hold magnetic resonance (MR) spectroscopic method for T2-corrected hepatic lipid measurement in phantoms and in humans.
MATERIALS AND METHODS: All experiments were institutional review board approved and HIPAA compliant; informed consent was obtained from all subjects. The 15-second breath-hold high-speed T2-corrected multiecho (HISTO) MR spectroscopic technique was developed to acquire multiple echoes in a single acquisition, which enables the quantification of water and lipid T2, and subsequently to provide a corrected measure of hepatic lipid fraction. The accuracy of T2-corrected MR spectroscopy was evaluated in eight lipid phantoms doped with iron to simulate variable T2 effects. The mean absolute error of the HISTO technique with the known lipid amounts, as well as with uncorrected MR spectroscopic measures, was evaluated. The HISTO sequence was performed in 25 male subjects (mean age, 23.0 years +/- 19.2 [standard deviation]) to evaluate measurement bias with conventional, uncorrected MR spectroscopy. Three additional male subjects (mean age, 30.0 years +/- 1.0) were examined to assess reproducibility by using analysis of variance testing within subject and between separate imaging sessions.
RESULTS: The absolute error in quantifying lipid fraction by using iron-doped lipid phantoms was less than 11% for the HISTO technique, compared with more than 50% for uncorrected MR spectroscopy. In the 25 human subjects, hepatic lipid measured by using HISTO differed significantly from that by using uncorrected MR spectroscopic methods by 5.1% +/- 2.6. Analysis of variance of three separate imaging sessions with the HISTO technique indicated no significant variance (P = .13) in three subjects.
CONCLUSION: HISTO is an accurate, reproducible MR spectroscopic sequence for quantifying hepatic lipid noninvasively. Evidence has shown this method to be feasible in vivo for clinical use.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19546430     DOI: 10.1148/radiol.2523082084

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  52 in total

Review 1.  Quantitative Assessment of Liver Fat with Magnetic Resonance Imaging and Spectroscopy.

Authors:  Scott B Reeder; Irene Cruite; Gavin Hamilton; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2011-09-16       Impact factor: 4.813

2.  Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration.

Authors:  Scott B Reeder; Houchun H Hu; Claude B Sirlin
Journal:  J Magn Reson Imaging       Date:  2012-07-06       Impact factor: 4.813

3.  Quantification of early fatty infiltration of the rotator cuff muscles: comparison of multi-echo Dixon with single-voxel MR spectroscopy.

Authors:  Christoph A Agten; Andrea B Rosskopf; Christian Gerber; Christian W A Pfirrmann
Journal:  Eur Radiol       Date:  2015-12-17       Impact factor: 5.315

4.  The effect of water suppression on the hepatic lipid quantification, as assessed by the LCModel, in a preclinical and clinical scenario.

Authors:  Amandine Coum; Fanny Noury; Elise Bannier; Karima Begriche; Bernard Fromenty; Yves Gandon; Hervé Saint-Jalmes; Giulio Gambarota
Journal:  MAGMA       Date:  2015-11-21       Impact factor: 2.310

5.  Hepatic fat quantification using the proton density fat fraction (PDFF): utility of free-drawn-PDFF with a large coverage area.

Authors:  Kun Young Kim; Ji Soo Song; Stephan Kannengiesser; Young Min Han
Journal:  Radiol Med       Date:  2015-05-08       Impact factor: 3.469

6.  Quantitative chemical shift-encoded MRI is an accurate method to quantify hepatic steatosis.

Authors:  Jens-Peter Kühn; Diego Hernando; Birger Mensel; Paul C Krüger; Till Ittermann; Julia Mayerle; Norbert Hosten; Scott B Reeder
Journal:  J Magn Reson Imaging       Date:  2013-10-10       Impact factor: 4.813

7.  Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

Authors:  Tess Armstrong; Karrie V Ly; Smruthi Murthy; Shahnaz Ghahremani; Grace Hyun J Kim; Kara L Calkins; Holden H Wu
Journal:  Pediatr Radiol       Date:  2018-05-04

Review 8.  Measurement of liver fat fraction and iron with MRI and MR spectroscopy techniques.

Authors:  Puneet Sharma; Maria Altbach; Jean-Philippe Galons; Bobby Kalb; Diego R Martin
Journal:  Diagn Interv Radiol       Date:  2014 Jan-Feb       Impact factor: 2.630

9.  Quantitative analysis of hepatic fat fraction by single-breath-holding MR spectroscopy with T₂ correction: phantom and clinical study with histologic assessment.

Authors:  Norio Hayashi; Tosiaki Miyati; Takashi Minami; Yumie Takeshita; Yasuji Ryu; Tsuyoshi Matsuda; Naoki Ohno; Takashi Hamaguchi; Kenichiro Kato; Toshinari Takamura; Osamu Matsui
Journal:  Radiol Phys Technol       Date:  2012-12-07

Review 10.  MRI of diffuse liver disease: characteristics of acute and chronic diseases.

Authors:  Surya Chundru; Bobby Kalb; Hina Arif-Tiwari; Puneet Sharma; James Costello; Diego R Martin
Journal:  Diagn Interv Radiol       Date:  2014 May-Jun       Impact factor: 2.630

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.