Literature DB >> 19543733

Brain ventricular wall movement assessed by a gated cine MR trueFISP sequence in patients treated with endoscopic third ventriculostomy.

Jérôme Hodel1, Philippe Decq, Alain Rahmouni, Sylvie Bastuji-Garin, Anne Maraval, Catherine Combes, Béchir Jarraya, Caroline Le Guérinel, André Gaston.   

Abstract

The purpose of this study was to investigate the value of brain ventricular wall movement assessment with a gated cine trueFISP MR sequence for the diagnosis of endoscopic third ventriculostomy (ETV) patency. Sixteen healthy volunteers and ten consecutive patients with noncommunicating hydrocephalus were explored with a MR scanner (Siemens, Avanto 1.5 T) before, 1 week and 3 months after ETV. TrueFISP was evaluated qualitatively (ventricular wall movement and CSF flow through ETV) and quantitatively [distance moved (DMLT) during a cardiac cycle by the lamina terminalis]. The third ventricle volume (TVV) was assessed. Statistical analysis was performed using nonparametric tests. There was no motion of the lamina terminalis (LT) detected on preoperative data. A pulsatile motion of the LT was found for patients with a patent ETV and for controls. DMLT and TVV were correlated (r = 0.79, P = 0.006). A transient dysfunction of ETV was successfully diagnosed on the trueFISP sequence with no motion of the LT or CSF flow observed. The trueFISP sequence appears reliable for the diagnosis of ETV patency and provides non-invasive assessment of the movement of the ventricular wall related to CSF pressure changes.

Entities:  

Mesh:

Year:  2009        PMID: 19543733     DOI: 10.1007/s00330-009-1477-4

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  32 in total

Review 1.  EthoVision: a versatile video tracking system for automation of behavioral experiments.

Authors:  L P Noldus; A J Spink; R A Tegelenbosch
Journal:  Behav Res Methods Instrum Comput       Date:  2001-08

2.  Left ventricular mass: manual and automatic segmentation of true FISP and FLASH cine MR images in dogs and pigs.

Authors:  Christopher J François; David S Fieno; Stephanie M Shors; J Paul Finn
Journal:  Radiology       Date:  2003-12-29       Impact factor: 11.105

3.  Flow artifacts in steady-state free precession cine imaging.

Authors:  Pippa Storey; Wei Li; Qun Chen; Robert R Edelman
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

4.  Ventricular volume following third ventriculostomy.

Authors:  T H Schwartz; B Ho; C J Prestigiacomo; J N Bruce; N A Feldstein; R R Goodman
Journal:  J Neurosurg       Date:  1999-07       Impact factor: 5.115

5.  Stereotactic third ventriculostomy: assessment of patency with MR imaging.

Authors:  C R Jack; P J Kelly
Journal:  AJNR Am J Neuroradiol       Date:  1989 May-Jun       Impact factor: 3.825

6.  Telemetric intraventricular pressure measurements after third ventriculocisternostomy in a patient with noncommunicating hydrocephalus.

Authors:  D M Frim; L C Goumnerova
Journal:  Neurosurgery       Date:  1997-12       Impact factor: 4.654

7.  Third ventriculostomy patency: comparison of findings at cine phase-contrast MR imaging and at direct exploration.

Authors:  T Fukuhara; S J Vorster; P Ruggieri; M G Luciano
Journal:  AJNR Am J Neuroradiol       Date:  1999-09       Impact factor: 3.825

Review 8.  Endoscopic third ventriculostomy for obstructive hydrocephalus.

Authors:  Dieter Hellwig; Joachim Andreas Grotenhuis; Wuttipong Tirakotai; Thomas Riegel; Dirk Michael Schulte; Bernhard Ludwig Bauer; Helmut Bertalanffy
Journal:  Neurosurg Rev       Date:  2004-11-27       Impact factor: 3.042

9.  Endoscopic third ventriculostomy.

Authors:  R F Jones; W A Stening; M Brydon
Journal:  Neurosurgery       Date:  1990-01       Impact factor: 4.654

10.  Complications of endoscopic third ventriculostomy.

Authors:  Henry W S Schroeder; Wulf-Rüdiger Niendorf; Michael R Gaab
Journal:  J Neurosurg       Date:  2002-06       Impact factor: 5.115

View more
  1 in total

1.  Cine MRI: a new approach to the diagnosis of scapholunate dissociation.

Authors:  I Langner; S Fischer; A Eisenschenk; S Langner
Journal:  Skeletal Radiol       Date:  2015-03-12       Impact factor: 2.199

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.