| Literature DB >> 19543733 |
Jérôme Hodel1, Philippe Decq, Alain Rahmouni, Sylvie Bastuji-Garin, Anne Maraval, Catherine Combes, Béchir Jarraya, Caroline Le Guérinel, André Gaston.
Abstract
The purpose of this study was to investigate the value of brain ventricular wall movement assessment with a gated cine trueFISP MR sequence for the diagnosis of endoscopic third ventriculostomy (ETV) patency. Sixteen healthy volunteers and ten consecutive patients with noncommunicating hydrocephalus were explored with a MR scanner (Siemens, Avanto 1.5 T) before, 1 week and 3 months after ETV. TrueFISP was evaluated qualitatively (ventricular wall movement and CSF flow through ETV) and quantitatively [distance moved (DMLT) during a cardiac cycle by the lamina terminalis]. The third ventricle volume (TVV) was assessed. Statistical analysis was performed using nonparametric tests. There was no motion of the lamina terminalis (LT) detected on preoperative data. A pulsatile motion of the LT was found for patients with a patent ETV and for controls. DMLT and TVV were correlated (r = 0.79, P = 0.006). A transient dysfunction of ETV was successfully diagnosed on the trueFISP sequence with no motion of the LT or CSF flow observed. The trueFISP sequence appears reliable for the diagnosis of ETV patency and provides non-invasive assessment of the movement of the ventricular wall related to CSF pressure changes.Entities:
Mesh:
Year: 2009 PMID: 19543733 DOI: 10.1007/s00330-009-1477-4
Source DB: PubMed Journal: Eur Radiol ISSN: 0938-7994 Impact factor: 5.315