Literature DB >> 19542896

Accuracy of colour duplex sonography for the diagnosis of renal artery stenosis.

Aso Saeed1, Göran Bergström, Karin Zachrisson, Gregor Guron, Elzbieta Nowakowska-Fortuna, Ellen Fredriksen, Lars Lönn, Gert Jensen, Hans Herlitz.   

Abstract

OBJECTIVE: To examine the diagnostic value of novel velocimetric colour duplex sonography indices in the screening of renal artery stenosis (RAS).
METHODS: We performed a retrospective analysis of all consecutively studied patients at our centre with suspected RAS, and a colour duplex sonography carried out at less than 4 months (mean 34 days) before renal angiography during a 6-year period (2002-2007). A significant RAS was defined as an at least 60% stenosis on angiography or a transstenotic mean arterial pressure gradient of at least 10 mmHg or both.
RESULTS: In a total of 169 patients, 111 stenotic and 206 nonstenotic kidneys were examined. The sensitivity and specificity for acceleration of blood flow in early systole (ACCmax) were 85 and 75%, respectively, and for the acceleration index (ACCmax/peak systolic velocity, AImax) 83 and 79%, respectively. Corresponding values in patients with estimated glomerular filtration rate of less than 30 ml/min/1.73 m2 were 90 and 73% (for ACCmax) and 74 and 88% (for AImax). In addition, the transstenotic mean arterial pressure gradient showed a significant, though weak, negative correlation to ACCmax (r = -0.26, P = 0.02) and AImax (r = -0.29, P = 0.01) in stenotic kidneys.
CONCLUSION: ACCmax and AImax provide similar, good diagnostic accuracy in the detection of a haemodynamically significant RAS, even in patients with markedly reduced glomerular filtration rate. Presumably, the lack of superiority of the novel index AImax could be explained by a highly homogenous methodological approach in the present single-centre study.

Entities:  

Mesh:

Year:  2009        PMID: 19542896     DOI: 10.1097/HJH.0b013e32832c417d

Source DB:  PubMed          Journal:  J Hypertens        ISSN: 0263-6352            Impact factor:   4.844


  3 in total

1.  Doppler ultrasound and renal artery stenosis: An overview.

Authors:  A Granata; F Fiorini; S Andrulli; F Logias; M Gallieni; G Romano; E Sicurezza; C E Fiore
Journal:  J Ultrasound       Date:  2009-10-12

2.  Computer-assisted detection of tardus parvus waveforms on Doppler ultrasound.

Authors:  Gowthaman Gunabushanam; John D Millet; Erik Stilp; Forrest W Crawford; Robert L McNamara; Leslie M Scoutt
Journal:  Ultrasound       Date:  2017-12-12

3.  Split renal function in patients with unilateral atherosclerotic renal artery stenosis-effect of renal angioplasty.

Authors:  Aso Saeed; Elzbieta Nowakowska- Fortuna; Gert Jensen
Journal:  Clin Kidney J       Date:  2017-07-03
  3 in total