Determination of the best electrode position for recording of the diaphragm compound muscle action potential.

Annie Dionne1, Anthony Parkes, Beata Engler, Bradley V Watson, Michael W Nicolle.   

Abstract

To determine the optimal recording site for phrenic nerve conduction studies, six different recording techniques were compared in 11 healthy volunteers (22 phrenic nerves). The mean diaphragm compound muscle action potential (CMAP) amplitude, side-to-side difference, and the number of studies with a false-positive result (CMAP amplitude <0.30 mV) were compared for each technique. The largest amplitude (0.65 +/- 0.23 mV, range 0.30-1.2 mV) with good right-left agreement (mean difference 0.15 mV) and no false positives was obtained using technique 1, where the G1 electrode was positioned 5 cm above the xiphoid process and G2 16 cm from G1 along the costal margin. This was also the easiest technique to perform. It does not require rib counting, which may be difficult and inaccurate, especially in overweight patients. At least one false positive occurred with each of the remaining five techniques.

Entities:  

Mesh:

Year:  2009        PMID: 19533636     DOI: 10.1002/mus.21290

Source DB:  PubMed          Journal:  Muscle Nerve        ISSN: 0148-639X            Impact factor:   3.217


  6 in total

Review 1.  Electrical stimulation for testing neuromuscular function: from sport to pathology.

Authors:  Guillaume Y Millet; Vincent Martin; Alain Martin; Samuel Vergès
Journal:  Eur J Appl Physiol       Date:  2011-05-18       Impact factor: 3.078

2.  Differences between diaphragmatic compound muscle action potentials recorded from over the sternum and lateral chest wall in healthy subjects.

Authors:  Gihan Younis; Noha El Sawy; Rehab Elnemr; Doaa Madkour
Journal:  Sci Rep       Date:  2022-05-27       Impact factor: 4.996

3.  Respiratory dysfunction in Charcot-Marie-Tooth disease type 1A.

Authors:  Mônica de Carvalho Alcântara; Marcello H Nogueira-Barbosa; Regina Maria França Fernandes; Geruza Alves da Silva; Charles Marques Lourenço; Heide H Sander; Wilson Marques Junior
Journal:  J Neurol       Date:  2015-03-13       Impact factor: 4.849

4.  Guidelines to electrode positioning for human and animal electrical impedance myography research.

Authors:  Benjamin Sanchez; Adam Pacheck; Seward B Rutkove
Journal:  Sci Rep       Date:  2016-09-02       Impact factor: 4.379

5.  Surface EMG-based quantification of inspiratory effort: a quantitative comparison with Pes.

Authors:  Jan Graßhoff; Eike Petersen; Franziska Farquharson; Max Kustermann; Hans-Joachim Kabitz; Philipp Rostalski; Stephan Walterspacher
Journal:  Crit Care       Date:  2021-12-20       Impact factor: 9.097

6.  Diaphragmatic CMAP Monitoring During Cryoballoon Procedures: Surface vs. Hepatic Recording Comparison and Limitations of This Approach.

Authors:  Lilith Tovmassian; Baptiste Maille; Linda Koutbi; Jérôme Hourdain; Elisa Martinez; Maxime Zabern; Jean-Claude Deharo; Frédéric Franceschi
Journal:  Front Cardiovasc Med       Date:  2022-02-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.