Literature DB >> 19531105

The effect of microrough surface treatment on miniscrews used as orthodontic anchors.

Chin-Shan Chang1, Tzer-Min Lee, Chih-Han Chang, Jia-Kuang Liu.   

Abstract

OBJECTIVES: The aim of this study was to investigate the effects of two different microrough surface treatments on miniscrews with loading over different time periods in vivo.
MATERIAL AND METHODS: Twenty-four New Zealand white rabbits were selected. One hundred and forty-four miniscrews with a machined (MA), sandblasted and acid-etched (SLA) or sandblasted and alkaline-etched (SL/NaOH) surface were implanted into the tibia of the rabbits. Then, orthodontic forces with Ni-Ti coils were applied immediately to two of the three miniscrews in each tibia, with the center one serving as the control. After 2, 4, 8 and 12 weeks, the rabbits were sacrificed. The removal torque value (RTV) was tested and bone-to-implant contact (BIC) was examined.
RESULTS: In most groups, there were no differences between the RTV in the unloaded and loaded conditions at different time periods. In the loaded condition, the RTV of the SLA groups increased significantly after 4 weeks of healing. The RTV in the SL/NaOH groups increased after 8 weeks, and reached a significant difference with the SLA groups after 12 weeks. After 12 weeks, the BIC in the SLA and SL/NaOH groups was higher than in the MA groups. A regression test revealed a moderate correlation between the BIC and the RTV.
CONCLUSIONS: There were no differences between the loaded and unloaded conditions in most groups. The RTV and BIC increased with time. In the loaded condition, the RTV of the SLA surface increased earlier, at 4 weeks, while the SL/NAOH group showed the highest RTV after 8 weeks.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19531105     DOI: 10.1111/j.1600-0501.2009.01728.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  9 in total

1.  Evaluation of miniscrew stability using an automatic embedding auxiliary skeletal anchorage device.

Authors:  Yasuhiko Oga; Hiroshi Tomonari; Sangho Kwon; Takaharu Kuninori; Takakazu Yagi; Shouichi Miyawaki
Journal:  Angle Orthod       Date:  2018-09-01       Impact factor: 2.079

2.  Comparison between microporous and nanoporous orthodontic miniscrews : An experimental study in rabbits.

Authors:  Yueh-Tse Lee; Eric Jein-Wein Liou; Sinn-Wen Chen
Journal:  J Orofac Orthop       Date:  2022-05-20       Impact factor: 1.938

3.  The development of novel bioactive porous titanium as a bone reconstruction material.

Authors:  Kazuya Doi; Reiko Kobatake; Yusuke Makihara; Yoshifumi Oki; Hanako Umehara; Takayasu Kubo; Kazuhiro Tsuga
Journal:  RSC Adv       Date:  2020-06-12       Impact factor: 4.036

Review 4.  Systematic review of mini-implant displacement under orthodontic loading.

Authors:  Manuel Nienkemper; Jörg Handschel; Dieter Drescher
Journal:  Int J Oral Sci       Date:  2013-12-20       Impact factor: 6.344

5.  Evaluation of osseous integration of titanium orthopedic screws with novel SLA treatment in porcine model.

Authors:  Tzu-Hsiang Lin; Hsin-Tai Hu; Hsueh-Chun Wang; Meng-Chian Wu; Shu-Wei Wu; Ming-Long Yeh
Journal:  PLoS One       Date:  2017-11-17       Impact factor: 3.240

6.  Antimicrobial peptide GL13K immobilized onto SLA-treated titanium by silanization: antibacterial effect against methicillin-resistant Staphylococcus aureus (MRSA).

Authors:  Yusang Li; Ruiying Chen; Fushi Wang; Xinjie Cai; Yining Wang
Journal:  RSC Adv       Date:  2022-03-02       Impact factor: 3.361

7.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

8.  Enhanced compatibility and initial stability of Ti6Al4V alloy orthodontic miniscrews subjected to anodization, cyclic precalcification, and heat treatment.

Authors:  Eun-Ju Oh; Thuy-Duong T Nguyen; Seung-Youp Lee; Young-Mi Jeon; Tae-Sung Bae; Jong-Gee Kim
Journal:  Korean J Orthod       Date:  2014-09-25       Impact factor: 1.372

9.  Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews.

Authors:  Soon-Dong Yun; Sung-Hwan Choi; Jung-Yul Cha; Hyung-Seog Yu; Kwang-Mahn Kim; Jin Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.