Literature DB >> 19530149

Using multivariate statistical methods to model the electrospray ionization response of GXG tripeptides based on multiple physicochemical parameters.

M A Raji1, P Frycák, C Temiyasathit, S B Kim, G Mavromaras, J-M Ahn, K A Schug.   

Abstract

Response factors were determined for twelve GXG peptides (where G stands for glycine and X is any of alanine [A], arginine [R], asparagine [N], aspartic acid [D], glycine [G], histidine [H], leucine [L], lysine [K], phenylalanine [F], serine [S], tyrosine [Y], valine [V]) by electrospray ionization mass spectrometry (ESI-MS). The response factors were measured using a novel flow injection method. This new method is based on the Gaussian distribution of analyte concentration resulting from band-broadening dispersion experienced by the analyte upon passage through an extended volume of PEEK tubing. This method removes the need for preparing a discrete series of standard solutions to assess concentration-dependent response. Relative response factors were calculated for each peptide with reference to GGG. The observed trends in the relative response factors were correlated with several analyte physicochemical parameters, chosen based on current understanding of ion release from charged droplets during the ESI process. These include analyte properties: nonpolar surface area; polar surface area; gas-phase basicity; proton affinity; and Log D. Multivariate statistical analysis using multiple linear regression, decision tree, and support vector regression models were investigated to assess their potential for predicting ESI response based on the analyte properties. The support vector regression model was more versatile and produced the least predictive error following 12-fold cross-validation. The effect of variation in solution pH on the relative response factors is highlighted, as evidenced by the different predictive models obtained for peptide response at two pH values (pH = 6.0 and 9.0). The relationship between physicochemical parameters and associated ionization efficiencies for GXG tripeptides is discussed based on the equilibrium partitioning model. Copyright 2009 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19530149     DOI: 10.1002/rcm.4141

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  3 in total

1.  Prediction of Mass Spectral Response Factors from Predicted Chemometric Data for Druglike Molecules.

Authors:  Christopher J Cramer; Joshua L Johnson; Amin M Kamel
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-10       Impact factor: 3.109

2.  Electrospray Ionization Efficiency Is Dependent on Different Molecular Descriptors with Respect to Solvent pH and Instrumental Configuration.

Authors:  Andreas Kiontke; Ariana Oliveira-Birkmeier; Andreas Opitz; Claudia Birkemeyer
Journal:  PLoS One       Date:  2016-12-01       Impact factor: 3.240

3.  Understanding the electrospray ionization response factors of per- and poly-fluoroalkyl substances (PFAS).

Authors:  Jeffrey R Enders; Grace M O'Neill; Jerry L Whitten; David C Muddiman
Journal:  Anal Bioanal Chem       Date:  2021-07-21       Impact factor: 4.478

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.