Literature DB >> 19526515

Rapid estimation of cartilage T2 based on double echo at steady state (DESS) with 3 Tesla.

Goetz H Welsch1, Klaus Scheffler, Tallal C Mamisch, Timothy Hughes, Steven Millington, Michael Deimling, Siegfried Trattnig.   

Abstract

The double-echo-steady-state (DESS) sequence generates two signal echoes that are characterized by a different contrast behavior. Based on these two contrasts, the underlying T2 can be calculated. For a flip-angle of 90 degrees , the calculated T2 becomes independent of T1, but with very low signal-to-noise ratio. In the present study, the estimation of cartilage T2, based on DESS with a reduced flip-angle, was investigated, with the goal of optimizing SNR, and simultaneously minimizing the error in T2. This approach was validated in phantoms and on volunteers. T2 estimations based on DESS at different flip-angles were compared with standard multiecho, spin-echo T2. Furthermore, DESS-T2 estimations were used in a volunteer and in an initial study on patients after cartilage repair of the knee. A flip-angle of 33 degrees was the best compromise for the combination of DESS-T2 mapping and morphological imaging. For this flip angle, the Pearson correlation was 0.993 in the phantom study (approximately 20% relative difference between SE-T2 and DESS-T2); and varied between 0.429 and 0.514 in the volunteer study. Measurements in patients showed comparable results for both techniques with regard to zonal assessment. This DESS-T2 approach represents an opportunity to combine morphological and quantitative cartilage MRI in a rapid one-step examination. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19526515     DOI: 10.1002/mrm.22036

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  35 in total

Review 1.  Quantitative MRI in the evaluation of articular cartilage health: reproducibility and variability with a focus on T2 mapping.

Authors:  Rachel K Surowiec; Erin P Lucas; Charles P Ho
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-30       Impact factor: 4.342

2.  Efficient imaging of midbrain nuclei using inverse double-echo steady-state acquisition.

Authors:  Ming-Long Wu; Hing-Chiu Chang; Tzu-Cheng Chao; Nan-Kuei Chen
Journal:  Med Phys       Date:  2015-07       Impact factor: 4.071

Review 3.  Rapid gradient-echo imaging.

Authors:  Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2012-10-23       Impact factor: 4.813

4.  Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS).

Authors:  Akshay S Chaudhari; Bragi Sveinsson; Catherine J Moran; Emily J McWalter; Ethan M Johnson; Tao Zhang; Garry E Gold; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2017-01-11       Impact factor: 4.668

5.  Dual-pathway multi-echo sequence for simultaneous frequency and T2 mapping.

Authors:  Cheng-Chieh Cheng; Chang-Sheng Mei; Jeffrey Duryea; Hsiao-Wen Chung; Tzu-Cheng Chao; Lawrence P Panych; Bruno Madore
Journal:  J Magn Reson       Date:  2016-02-04       Impact factor: 2.229

6.  Optimizing MR Scan Design for Model-Based ${T}_{1}$ , ${T}_{2}$ Estimation From Steady-State Sequences.

Authors:  Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2016-10-04       Impact factor: 10.048

Review 7.  Magnetic resonance fingerprinting review part 2: Technique and directions.

Authors:  Debra F McGivney; Rasim Boyacıoğlu; Yun Jiang; Megan E Poorman; Nicole Seiberlich; Vikas Gulani; Kathryn E Keenan; Mark A Griswold; Dan Ma
Journal:  J Magn Reson Imaging       Date:  2019-07-25       Impact factor: 4.813

8.  A simple analytic method for estimating T2 in the knee from DESS.

Authors:  B Sveinsson; A S Chaudhari; G E Gold; B A Hargreaves
Journal:  Magn Reson Imaging       Date:  2016-12-23       Impact factor: 2.546

9.  Variability of CubeQuant T1ρ, quantitative DESS T2, and cones sodium MRI in knee cartilage.

Authors:  C D Jordan; E J McWalter; U D Monu; R D Watkins; W Chen; N K Bangerter; B A Hargreaves; G E Gold
Journal:  Osteoarthritis Cartilage       Date:  2014-10       Impact factor: 6.576

10.  Five-minute knee MRI for simultaneous morphometry and T2 relaxometry of cartilage and meniscus and for semiquantitative radiological assessment using double-echo in steady-state at 3T.

Authors:  Akshay S Chaudhari; Marianne S Black; Susanne Eijgenraam; Wolfgang Wirth; Susanne Maschek; Bragi Sveinsson; Felix Eckstein; Edwin H G Oei; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2017-11-01       Impact factor: 4.813

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.