Literature DB >> 19526513

Robust correction of spike noise: application to diffusion tensor imaging.

S Chavez1, P Storey, S J Graham.   

Abstract

Echo-planar imaging (EPI) -based diffusion tensor imaging (DTI) is particularly prone to spike noise. However, existing spike noise correction methods are impractical for corrupted DTI data because the methods correct the complex MRI signal, which is not usually stored on clinical MRI systems. The present work describes a novel Outlier Detection De-spiking technique (ODD) that consists of three steps: detection, localization, and correction. Using automated outlier detection schemes, ODD exploits the data redundancy available in DTI data sets that are acquired with a minimum of six different diffusion-weighted images (DWIs) with similar signal and noise properties. A mathematical formulation, describing the effects of spike noise on magnitude images, yields appropriate measures for an outlier detection scheme used for spike detection while a normalization-dependent outlier detection scheme is used for spike localization. ODD performs accurately on diverse DTI data sets corrupted by spike noise and can be used for automated control of DTI data quality. ODD can also be extended to other MRI applications with data redundancy, such as dynamic imaging and functional MRI. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19526513     DOI: 10.1002/mrm.22019

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  7 in total

1.  Quantitative quality assurance in a multicenter HARDI clinical trial at 3T.

Authors:  Xiaopeng Zhou; Ken E Sakaie; Josef P Debbins; John E Kirsch; Curtis Tatsuoka; Robert J Fox; Mark J Lowe
Journal:  Magn Reson Imaging       Date:  2016-08-30       Impact factor: 2.546

Review 2.  Diffusion MRI and its Role in Neuropsychology.

Authors:  Bryon A Mueller; Kelvin O Lim; Laura Hemmy; Jazmin Camchong
Journal:  Neuropsychol Rev       Date:  2015-08-09       Impact factor: 7.444

3.  A novel DTI-QA tool: Automated metric extraction exploiting the sphericity of an agar filled phantom.

Authors:  Sofia Chavez; Joseph Viviano; Mojdeh Zamyadi; Peter B Kingsley; Peter Kochunov; Stephen Strother; Aristotle Voineskos
Journal:  Magn Reson Imaging       Date:  2017-10-17       Impact factor: 2.546

4.  Using the robust principal component analysis algorithm to remove RF spike artifacts from MR images.

Authors:  Adrienne E Campbell-Washburn; David Atkinson; Zoltan Nagy; Rachel W Chan; Oliver Josephs; Mark F Lythgoe; Roger J Ordidge; David L Thomas
Journal:  Magn Reson Med       Date:  2015-07-20       Impact factor: 4.668

5.  A New Phased-Array Magnetic Resonance Imaging Receive-Only Coil for HBO2 Studies.

Authors:  Azma Mareyam; Erik Shank; Lawrence L Wald; Michael K Qin; Giorgio Bonmassar
Journal:  Sensors (Basel)       Date:  2022-08-14       Impact factor: 3.847

6.  A hitchhiker's guide to diffusion tensor imaging.

Authors:  José M Soares; Paulo Marques; Victor Alves; Nuno Sousa
Journal:  Front Neurosci       Date:  2013-03-12       Impact factor: 4.677

7.  Different patterns of white matter degeneration using multiple diffusion indices and volumetric data in mild cognitive impairment and Alzheimer patients.

Authors:  Gilberto Sousa Alves; Laurence O'Dwyer; Alina Jurcoane; Viola Oertel-Knöchel; Christian Knöchel; David Prvulovic; Felipe Sudo; Carlos Eduardo Alves; Letice Valente; Denise Moreira; Fabian Fußer; Fabian Fuβer; Tarik Karakaya; Johannes Pantel; Eliasz Engelhardt; Jerson Laks
Journal:  PLoS One       Date:  2012-12-31       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.