Literature DB >> 27587227

Quantitative quality assurance in a multicenter HARDI clinical trial at 3T.

Xiaopeng Zhou1, Ken E Sakaie1, Josef P Debbins2, John E Kirsch3, Curtis Tatsuoka4, Robert J Fox5, Mark J Lowe6.   

Abstract

A phantom-based quality assurance (QA) protocol was developed for a multicenter clinical trial including high angular resolution diffusion imaging (HARDI). A total of 27 3T MR scanners from 2 major manufacturers, GE (Discovery and Signa scanners) and Siemens (Trio and Skyra scanners), were included in this trial. With this protocol, agar phantoms doped to mimic relaxation properties of brain tissue are scanned on a monthly basis, and quantitative procedures are used to detect spiking and to evaluate eddy current and Nyquist ghosting artifacts. In this study, simulations were used to determine alarm thresholds for minimal acceptable signal-to-noise ratio (SNR). Our results showed that spiking artifact was the most frequently observed type of artifact. Overall, Trio scanners exhibited less eddy current distortion than GE scanners, which in turn showed less distortion than Skyra scanners. This difference was mainly caused by the different sequences used on these scanners. The SNR for phantom scans was closely correlated with the SNR from volunteers. Nearly all of the phantom measurements with artifact-free images were above the alarm threshold, suggesting that the scanners are stable longitudinally. Software upgrades and hardware replacement sometimes affected SNR substantially but sometimes did not. In light of these results, it is important to monitor longitudinal SNR with phantom QA to help interpret potential effects on in vivo measurements. Our phantom QA procedure for HARDI scans was successful in tracking scanner performance and detecting unwanted artifacts. Copyright Â
© 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  HARDI; Multicenter; Phantom; QA; SNR

Mesh:

Year:  2016        PMID: 27587227      PMCID: PMC5125830          DOI: 10.1016/j.mri.2016.08.022

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  30 in total

1.  Multicenter stability of diffusion tensor imaging measures: a European clinical and physical phantom study.

Authors:  Stefan J Teipel; Sigrid Reuter; Bram Stieltjes; Julio Acosta-Cabronero; Ulrike Ernemann; Andreas Fellgiebel; Massimo Filippi; Giovanni Frisoni; Frank Hentschel; Frank Jessen; Stefan Klöppel; Thomas Meindl; Petra J W Pouwels; Karl-Heinz Hauenstein; Harald Hampel
Journal:  Psychiatry Res       Date:  2011-11-09       Impact factor: 3.222

2.  High angular resolution diffusion imaging reveals intravoxel white matter fiber heterogeneity.

Authors:  David S Tuch; Timothy G Reese; Mette R Wiegell; Nikos Makris; John W Belliveau; Van J Wedeen
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

Review 3.  Report on a multicenter fMRI quality assurance protocol.

Authors:  Lee Friedman; Gary H Glover
Journal:  J Magn Reson Imaging       Date:  2006-06       Impact factor: 4.813

Review 4.  Advances in functional and structural MR image analysis and implementation as FSL.

Authors:  Stephen M Smith; Mark Jenkinson; Mark W Woolrich; Christian F Beckmann; Timothy E J Behrens; Heidi Johansen-Berg; Peter R Bannister; Marilena De Luca; Ivana Drobnjak; David E Flitney; Rami K Niazy; James Saunders; John Vickers; Yongyue Zhang; Nicola De Stefano; J Michael Brady; Paul M Matthews
Journal:  Neuroimage       Date:  2004       Impact factor: 6.556

5.  Anatomic connectivity assessed using pathway radial diffusivity is related to functional connectivity in monosynaptic pathways.

Authors:  Mark J Lowe; Katherine A Koenig; Erik B Beall; Ken A Sakaie; Lael Stone; Robert Bermel; Michael D Phillips
Journal:  Brain Connect       Date:  2014-09

6.  Diffusion coefficient measurement using a temperature-controlled fluid for quality control in multicenter studies.

Authors:  Thomas L Chenevert; Craig J Galbán; Marko K Ivancevic; Susan E Rohrer; Frank J Londy; Thomas C Kwee; Charles R Meyer; Timothy D Johnson; Alnawaz Rehemtulla; Brian D Ross
Journal:  J Magn Reson Imaging       Date:  2011-10       Impact factor: 4.813

7.  High angular resolution diffusion imaging probabilistic tractography of the auditory radiation.

Authors:  J I Berman; M R Lanza; L Blaskey; J C Edgar; T P L Roberts
Journal:  AJNR Am J Neuroradiol       Date:  2013-03-14       Impact factor: 3.825

8.  Test liquids for quantitative MRI measurements of self-diffusion coefficient in vivo.

Authors:  P S Tofts; D Lloyd; C A Clark; G J Barker; G J Parker; P McConville; C Baldock; J M Pope
Journal:  Magn Reson Med       Date:  2000-03       Impact factor: 4.668

9.  Identical, but not the same: intra-site and inter-site reproducibility of fractional anisotropy measures on two 3.0T scanners.

Authors:  Christian Vollmar; Jonathan O'Muircheartaigh; Gareth J Barker; Mark R Symms; Pamela Thompson; Veena Kumari; John S Duncan; Mark P Richardson; Matthias J Koepp
Journal:  Neuroimage       Date:  2010-03-23       Impact factor: 6.556

10.  Multi-centre reproducibility of diffusion MRI parameters for clinical sequences in the brain.

Authors:  Matthew Grech-Sollars; Patrick W Hales; Keiko Miyazaki; Felix Raschke; Daniel Rodriguez; Martin Wilson; Simrandip K Gill; Tina Banks; Dawn E Saunders; Jonathan D Clayden; Matt N Gwilliam; Thomas R Barrick; Paul S Morgan; Nigel P Davies; James Rossiter; Dorothee P Auer; Richard Grundy; Martin O Leach; Franklyn A Howe; Andrew C Peet; Chris A Clark
Journal:  NMR Biomed       Date:  2015-04       Impact factor: 4.044

View more
  6 in total

1.  A novel DTI-QA tool: Automated metric extraction exploiting the sphericity of an agar filled phantom.

Authors:  Sofia Chavez; Joseph Viviano; Mojdeh Zamyadi; Peter B Kingsley; Peter Kochunov; Stephen Strother; Aristotle Voineskos
Journal:  Magn Reson Imaging       Date:  2017-10-17       Impact factor: 2.546

2.  Scan-rescan repeatability and cross-scanner comparability of DTI metrics in healthy subjects in the SPRINT-MS multicenter trial.

Authors:  Xiaopeng Zhou; Ken E Sakaie; Josef P Debbins; Sridar Narayanan; Robert J Fox; Mark J Lowe
Journal:  Magn Reson Imaging       Date:  2018-07-23       Impact factor: 2.546

3.  Vitamin D Levels and Visual System Measurements in Progressive Multiple Sclerosis: A Cross-sectional Study.

Authors:  Justin R Abbatemarco; Robert J Fox; Hong Li; Robert A Bermel; Daniel Ontaneda
Journal:  Int J MS Care       Date:  2020-04-28

Review 4.  The sensitivity of diffusion MRI to microstructural properties and experimental factors.

Authors:  Maryam Afzali; Tomasz Pieciak; Sharlene Newman; Eleftherios Garyfallidis; Evren Özarslan; Hu Cheng; Derek K Jones
Journal:  J Neurosci Methods       Date:  2020-10-02       Impact factor: 2.390

5.  Influence of equipment changes on MRI measures of brain atrophy and brain microstructure in a placebo-controlled trial of ibudilast in progressive multiple sclerosis.

Authors:  Ken Sakaie; Janel K Fedler; Jon W Yankey; Kunio Nakamura; Josef Debbins; Mark J Lowe; Paola Raska; Robert J Fox
Journal:  Mult Scler J Exp Transl Clin       Date:  2021-05-18

Review 6.  Variability and Standardization of Quantitative Imaging: Monoparametric to Multiparametric Quantification, Radiomics, and Artificial Intelligence.

Authors:  Akifumi Hagiwara; Shohei Fujita; Yoshiharu Ohno; Shigeki Aoki
Journal:  Invest Radiol       Date:  2020-09       Impact factor: 10.065

  6 in total