Literature DB >> 19524918

The effects of measurement site and ambient temperature on body temperature values in healthy older adults: a cross-sectional comparative study.

Shu-Hua Lu1, Yu-Tzu Dai, Chung-Jen Yen.   

Abstract

BACKGROUND: Accurate baseline body temperature measurement is essential for assessment. Tympanic membrane temperature (TMT) measurement is popular, but there is no consensus on whether it is as accurate as oral temperature (OT) for use with the elderly at varying ambient temperature levels.
OBJECTIVES: To test agreement between TMT and OT measurement of body temperature among an elderly population; and to explore whether agreement between the two sites depends on ambient temperature.
DESIGN: A cross-sectional comparison study.
METHODS: Two samples of older community-dwelling adults were recruited from 17 community senior citizen centers in Taipei, Taiwan in winter (n=262) and summer (n=257) of 2007. TMT and OT were simultaneously measured by electronic infrared ear thermometer and electronic digital thermometer. Ambient temperatures measured by digital thermo-hygrometer of the data collection setting were recorded when body temperature was taken.
RESULTS: In winter mean TMT was 36.64 degrees C (S.D. 0.37), and mean OT was 36.74 degrees C (S.D. 0.18). In summer, the mean TMT was 37.05 degrees C (S.D. 0.30) and mean OT was 36.85 degrees C (S.D. 0.22). The relationship between TMT and OT were r=0.42 (p<0.001) in winter and r=0.57 (p<0.001) in summer. The values of OT were used as standard to assess the accuracy of the measurement. The bias between TMT and OT was -0.10 degrees C (S.D. 0.34) and 95% limits of agreement were 0.57 and -0.77 degrees C in winter; and bias was 0.20 degrees C (S.D. 0.25) and 95% limits of agreement were 0.69 and -0.29 degrees C in summer. The findings of this study demonstrate that the TMT has high variability that may under or over estimate body temperatures.
CONCLUSIONS: There is a lack of agreement in body temperatures values between TMT and OT in community-dwelling elderly in both winter and summer. OT was more stable than TMT regardless of ambient temperature influences. Therefore, the oral cavity is preferable to the TM site for temperature measurement in alert elderly. The limitation of this study is that hospitalized patients who are most likely to need temperature measurement are not included in this study.

Entities:  

Mesh:

Year:  2009        PMID: 19524918     DOI: 10.1016/j.ijnurstu.2009.05.002

Source DB:  PubMed          Journal:  Int J Nurs Stud        ISSN: 0020-7489            Impact factor:   5.837


  2 in total

1.  Ice cube stimulation helps to improve dysgeusia.

Authors:  Rie Fujiyama; Shingo Ishitobi; Keiko Honda; Yukio Okada; Kumiko Oi; Kazuo Toda
Journal:  Odontology       Date:  2010-02-16       Impact factor: 2.634

2.  Evaluation of a wearable wireless device with artificial intelligence, iThermonitor WT705, for continuous temperature monitoring for patients in surgical wards: a prospective comparative study.

Authors:  Ruihua Xu; Renrong Gong; Yuwei Liu; Changqing Liu; Min Gao; Yan Wang; Yangjing Bai
Journal:  BMJ Open       Date:  2020-11-18       Impact factor: 2.692

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.