Literature DB >> 19523092

Intra-observer and inter-observer variation of Hertel exophthalmometry.

Andrew K C Lam1, Chun-fai Lam, Wai-kit Leung, Pui-kwan Hung.   

Abstract

PURPOSE: This study investigated the intra-observer and inter-observer variation of Hertel exophthalmometry.
METHODS: Seventy normal Chinese adults had bilateral exophthalmometry performed by two examiners. The two examiners were masked to the measurement results. One examiner did the measurement twice and the other examiner measured it once; the order was randomised. The same Hertel exophthalmometer was used throughout the study. The Bland-Altman method was used to analyse the intra-observer and inter-observer agreement.
RESULTS: The mean intra-observer and inter-observer agreements on the interorbital distance (IOD) were +/-3.31 mm and +/-6.39 mm, respectively. The intra-observer exophthalmometry difference was -0.01 +/- 0.61 mm for the right eye and 0.09 +/- 0.56 mm for the left eye. Agreements were +/-1.19 mm and +/-1.09 mm for the right and left eyes, respectively. The inter-observer exophthalmometry difference was -0.61 +/- 0.89 mm for the right eye and -0.49 +/- 0.80 mm for the left eye. Agreements were +/-1.74 mm and +/-1.57 mm for the right and left eyes, respectively. There was no significant intra-observer difference but the inter-observer difference was significant on both the IOD and exophthalmometry.
CONCLUSION: Good intra-observer agreement was demonstrated using Hertel exophthalmometry. The inter-observer agreement was clinically acceptable.

Mesh:

Year:  2009        PMID: 19523092     DOI: 10.1111/j.1475-1313.2008.00617.x

Source DB:  PubMed          Journal:  Ophthalmic Physiol Opt        ISSN: 0275-5408            Impact factor:   3.117


  12 in total

1.  Computed Tomography-Based Prediction of Exophthalmos Reduction After Deep Lateral Orbital Wall Decompression for Graves' Orbitopathy.

Authors:  Yoshiyuki Kitaguchi; Yasuhiro Takahashi; Hirohiko Kakizaki
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-10-23       Impact factor: 3.117

2.  Axial Globe Position Measurement: A Prospective Multicenter Study by the International Thyroid Eye Disease Society.

Authors:  Chad M Bingham; Jennifer A Sivak-Callcott; Matthew J Gurka; John Nguyen; Jeffery P Hogg; Steve E Feldon; Aaron Fay; Lay-Leng Seah; Diego Strianese; Vikram D Durairaj; Jimmy Uddin; Martin H Devoto; Matheson Harris; Justin Saunders; Tammy H Osaki; Audrey Looi; Livia Teo; Brett W Davies; Andrea Elefante; Sunny Shen; Tony Realini; William Fischer; Michael Kazim
Journal:  Ophthalmic Plast Reconstr Surg       Date:  2016 Mar-Apr       Impact factor: 1.746

3.  Validation of Modified Hertel Exophthalmometer.

Authors:  Rizwana Fathima Jamal; Emmanuel Azariah; Deepak Pandyan; Ravindran Chinnaswami
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-09-11

4.  Clinical and Radiological Findings in Patients with Newly Diagnosed Graves' Ophthalmopathy.

Authors:  Yakup Cevik; Hande Taylan Sekeroglu; Burce Ozgen; Kadriye Erkan Turan; Ali Sefik Sanac
Journal:  Int J Endocrinol       Date:  2021-04-30       Impact factor: 3.257

5.  Normal values of Hertel exophthalmometry in a Chinese Han population from Shenyang, Northeast China.

Authors:  Dan Wu; Xin Liu; Di Wu; Xin Di; Haixia Guan; Zhongyan Shan; Weiping Teng
Journal:  Sci Rep       Date:  2015-02-23       Impact factor: 4.379

6.  Identification and Functional Characterization of ST3GAL5 and ST8SIA1 Variants in Patients with Thyroid-Associated Ophthalmopathy.

Authors:  Hyo Jin Park; Ju Hee Kim; Jin Sook Yoon; Yang Ji Choi; Yoon Hee Choi; Koung Hoon Kook; Ji Ha Choi
Journal:  Yonsei Med J       Date:  2017-11       Impact factor: 2.759

7.  A Novel Three-Dimensional Vector Analysis of Axial Globe Position in Thyroid Eye Disease.

Authors:  Jie Guo; Jiang Qian; Yifei Yuan; Rui Zhang; Wenhu Huang
Journal:  J Ophthalmol       Date:  2017-04-09       Impact factor: 1.909

8.  Hertel exophthalmometer versus computed tomography scan in proptosis estimation in thyroid-associated orbitopathy.

Authors:  Na Ri Park; Jun Hyung Moon; Jeong Kyu Lee
Journal:  Clin Ophthalmol       Date:  2019-08-02

9.  A Comparative Study of Clinical vs. Digital Exophthalmometry Measurement Methods.

Authors:  Tháıs de Sous Pereira; Cristina Hiromi Kuniyoshi; Cristiane de Almeida Leite; Eloisa M M S Gebrim; Mário L R Monteiro; Allan C Pieroni Gonçalves
Journal:  J Ophthalmol       Date:  2020-03-23       Impact factor: 1.909

10.  The feasibility analysis of calculating proptosis by simple Heron's formula.

Authors:  Weili Zhang; Qinying Huang; Yile Chen; Jinying Li
Journal:  PLoS One       Date:  2020-06-01       Impact factor: 3.752

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.