Anjan Gupta1, Suhail Allaqaband, Tanvir Bajwa.
Abstract
Patients who suffer cardiogenic shock after cardiac arrest have a very poor prognosis. Left ventricular assist devices have proven to be useful in these patients to improve survival. Recently introduced percutaneous assist devices are easier to use and can be inserted quickly in the catheterization laboratory. We describe a case where intra-aortic balloon pump by itself was not enough to provide hemodynamic support in a patient with cardiogenic shock after cardiac arrest. The Impella Recover LP 2.5 system (ABIOMED, Inc., Danvers, MA) was successfully used along with the balloon pump for hemodynamic support and resulted in dramatic improvement of the patient's condition. Copyright 2009 Wiley-Liss, Inc.Entities:
Mesh:
Substances:
Year: 2009 PMID: 19521993 DOI: 10.1002/ccd.22140