Literature DB >> 1952136

Depth of placement of left double-lumen endobronchial tubes.

J B Brodsky1, J L Benumof, J Ehrenwerth, G T Ozaki.   

Abstract

Data on the normal depth of insertion of double-lumen tubes have not been published. We studied 101 adult patients undergoing thoracic operations whose tracheas were intubated with a left double-lumen tube. A fiberoptic bronchoscope was introduced into the tracheal lumen, and the tube position was adjusted until the cephalad surface of the bronchial cuff was immediately below the carinal bifurcation. The average depth of insertion for both male and female patients 170 cm tall was 29 cm, and for each 10-cm increase or decrease in height, average placement depth was increased or decreased 1 cm. The correlation between depth of insertion and height was highly significant (P less than 0.0001) for both male and female patients. As depth of DLT insertion at any given height was normally distributed, a technique to confirm correct double-lumen tube position always should be used after initial placement.

Entities:  

Mesh:

Year:  1991        PMID: 1952136     DOI: 10.1213/00000539-199111000-00010

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  10 in total

Review 1.  [Airway management for one-lung ventilation].

Authors:  J Motsch; K Wiedemann; J Roggenbach
Journal:  Anaesthesist       Date:  2005-06       Impact factor: 1.041

2.  Movements of the double-lumen endotracheal tube due to lateral position with head rotation and tube fixation: a Thiel-embalmed cadaver study.

Authors:  Daisuke Maruyama; Tomohiro Chaki; Masahito Omote; Naoyuki Hirata; Masanori Yamauchi; Michiaki Yamakage
Journal:  Surg Radiol Anat       Date:  2014-12-28       Impact factor: 1.246

3.  Assessment of airway length of Korean adults and children for otolaryngology and ophthalmic surgery using a fiberoptic bronchoscope.

Authors:  Hae Jin Pak; Boo Hwi Hong; Won Hyung Lee
Journal:  Korean J Anesthesiol       Date:  2010-10-21

4.  Comparison of a tube-holder (Rescuefix) versus tape-tying for minimizing double-lumen tube displacement during lateral positioning in thoracic surgery: A prospective, randomized controlled study.

Authors:  Sung Hye Byun; Su Hwang Kang; Jong Hae Kim; Taeha Ryu; Baek Jin Kim; Jin Yong Jung
Journal:  Medicine (Baltimore)       Date:  2016-08       Impact factor: 1.889

5.  Combined use of a double-lumen tube and Fogarty catheter to prevent the endobronchial spread of infection: a case report.

Authors:  Jaewon Kim; Hyelim Lee; Han Park; Chang-Young Jeong
Journal:  Korean J Anesthesiol       Date:  2016-08-18

6.  Selection of an appropriate left-sided double-lumen tube size for one-lung ventilation among Asians.

Authors:  Siti Salwani Ideris; Muhamad Rahimi Che Hassan; Mohd Ramzisham Abdul Rahman; Joanna Su Min Ooi
Journal:  Ann Card Anaesth       Date:  2017 Jan-Mar

7.  Effect-site concentration of remifentanil required to blunt haemodynamic responses during tracheal intubation: A randomized comparison between single- and double-lumen tubes.

Authors:  Tae Kyong Kim; Deok Man Hong; Seo Hee Lee; Hyesun Paik; Se Hee Min; Jeong-Hwa Seo; Chul-Woo Jung; Jae-Hyon Bahk
Journal:  J Int Med Res       Date:  2017-07-21       Impact factor: 1.671

8.  Insertion depth of left-sided double-lumen endobroncheal tube: A new predictive formula.

Authors:  Abdelazeem Eldawlatly; Ahmed Alqatari; Naveed Kanchi; Amir Marzouk
Journal:  Saudi J Anaesth       Date:  2019 Jul-Sep

Review 9.  Lung isolation, one-lung ventilation and hypoxaemia during lung isolation.

Authors:  Atul Purohit; Suresh Bhargava; Vandana Mangal; Vinod Kumar Parashar
Journal:  Indian J Anaesth       Date:  2015-09

10.  Augmentation of curved tip of left-sided double-lumen tubes to reduce right bronchial misplacement: A randomized controlled trial.

Authors:  Jeong-Hwa Seo; Susie Yoon; Se-Hee Min; Hyung Sang Row; Jae-Hyon Bahk
Journal:  PLoS One       Date:  2019-01-15       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.