BACKGROUND: Double-lumen endotracheal tubes (DLTs) are often displaced during change from the supine to the lateral decubitus position. The aim of this study was to determine whether Rescuefix, a recently developed tube-holder device, is more effective than the traditional tape-tying method for tube security during lateral positioning.Entities:
Mesh:
Year: 2016 PMID: 27495093 PMCID: PMC4979847 DOI: 10.1097/MD.0000000000004486
Source DB: PubMed Journal: Medicine (Baltimore) ISSN: 0025-7974 Impact factor: 1.889
Figure 1(A) Photograph of the Rescuefix tube-holder device. The plastic tube clamp grips the endotracheal tube. The flexible flange with a foam cushion can adapt to the patient's face. The length-adjustable neck tape wraps the patient's neck with a Velcro strap. (B) Photograph of the Rescuefix device applied to a patient in the lateral decubitus position.
Figure 2Measurement of depths using the FOB. (A) The tape is attached on the shaft of the FOB approximately 40 cm proximally from the tip. (B) When the tip of the FOB reaches the tracheal or bronchial carina, the point of contact with the elbow connector of the DLT is marked on the shaft of the FOB for measuring “tracheal depth” or “bronchial depth.” Tracheal depth denotes the distance from the tracheal carina to the elbow connector of the DLT. Bronchial depth denotes the distance from the bronchial carina to the elbow connector. DLT = double-lumen endotracheal tube, FOB = fiberoptic bronchoscope.
Figure 3CONSORT flow diagram. DLT = double-lumen endotracheal tube.
Patient characteristics.
Figure 4Changes in tracheal depth and bronchial depth during lateral positioning. Data are expressed as the mean ± standard deviation. ∗P < 0.05 when compared between groups. Tracheal depth denotes the distance from the tracheal carina to the elbow connector of the DLT. Bronchial depth denotes the distance from the bronchial carina to the elbow connector. DLT = double-lumen endotracheal tube, R group = Rescuefix group, T group = tape group.
Figure 5Incidence of DLT repositioning due to inappropriate position. Data are expressed as the number of patients (%). ∗P < 0.05 when compared between groups. DLT = double-lumen endotracheal tube, R group = Rescuefix group, T group = tape group.
Variables associated with DLT displacement.
Direction of displacement of double-lumen tube after lateral positioning.