Literature DB >> 19521061

Inert gas washout: theoretical background and clinical utility in respiratory disease.

Paul D Robinson1, Michael D Goldman, Per M Gustafsson.   

Abstract

Inert gas washout was first described more than 60 years ago and 2 principal tests have been developed from it: the single breath and multiple breath washout (MBW) techniques. The invention of fast responding gas analysers almost 60 years ago and small computers 30 years later have facilitated breath-by-breath analysis and the development of sophisticated analysis techniques. It is now possible to detect not only the degree of pulmonary ventilation inhomogeneity, but also to gain important insight into the location of the underlying disease process. While single breath washout requires a full vital capacity effort, tidal breathing during the multiple breath test requires minimal co-operation and co-ordination, and is feasible in subjects of all ages. Available MBW normative data from parameters, such as the lung clearance index, appears to vary minimally with age, making MBW particularly useful to follow children longitudinally. Multiple breath inert gas washout has demonstrated improved sensitivity, in comparison to spirometry, in the early detection of a number of important disease processes, including cystic fibrosis. Despite this, these important techniques remain under-utilised in the clinical setting and there is a lack of commercially available devices currently available. The recent resurgence of research in this area has produced a large number of important studies and a pronounced international interest has developed in these techniques. This review article will provide an overview of the theoretical background of inert gas washout and analysis indices, review important physiological and clinical insights gained from research to date (as well as from our own experience) to illustrate its utility, and outline the challenges that lie ahead in incorporating these techniques into the mainstream clinical setting. (c) 2009 S. Karger AG, Basel.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19521061     DOI: 10.1159/000225373

Source DB:  PubMed          Journal:  Respiration        ISSN: 0025-7931            Impact factor:   3.580


  40 in total

1.  Numerical modelling and analysis of peripheral airway asymmetry and ventilation in the human adult lung.

Authors:  F S Henry; C J Llapur; A Tsuda; R S Tepper
Journal:  J Biomech Eng       Date:  2012-06       Impact factor: 2.097

2.  Influence of end-expiratory level and tidal volume on gravitational ventilation distribution during tidal breathing in healthy adults.

Authors:  Silvia Schnidrig; Carmen Casaulta; Andreas Schibler; Thomas Riedel
Journal:  Eur J Appl Physiol       Date:  2012-08-08       Impact factor: 3.078

Review 3.  Long-term outcomes of early-onset wheeze and asthma.

Authors:  Roni Grad; Wayne J Morgan
Journal:  J Allergy Clin Immunol       Date:  2012-06-26       Impact factor: 10.793

4.  New time-saving predictor algorithm for multiple breath washout in adolescents.

Authors:  Jonathan Grønbæk; Henrik Wegener Hallas; Lambang Arianto; Knud Pedersen; Arne Thomsen; Bo Lund Chawes; Hans Bisgaard
Journal:  Pediatr Res       Date:  2016-03-22       Impact factor: 3.756

5.  Use of lung clearance index to assess the response to intravenous treatment in cystic fibrosis.

Authors:  E Hatziagorou; V Avramidou; F Kirvassilis; J Tsanakas
Journal:  Hippokratia       Date:  2015 Jan-Mar       Impact factor: 0.471

6.  Abnormal Lung Clearance Index in Cystic Fibrosis Children with Normal FEV1 and Single-Breath Nitrogen Washout Test.

Authors:  Ajay S Kasi; Choo Phei Wee; Thomas G Keens; Danieli B Salinas
Journal:  Lung       Date:  2021-01-03       Impact factor: 2.584

7.  Ventilation heterogeneity measured by multiple breath inert gas testing is not affected by inspired oxygen concentration in healthy humans.

Authors:  Susan R Hopkins; Ann R Elliott; G Kim Prisk; Chantal Darquenne
Journal:  J Appl Physiol (1985)       Date:  2017-03-09

8.  Multiple-Breath Washout as a Lung Function Test in Cystic Fibrosis. A Cystic Fibrosis Foundation Workshop Report.

Authors:  Padmaja Subbarao; Carlos Milla; Paul Aurora; Jane C Davies; Stephanie D Davis; Graham L Hall; Sonya Heltshe; Philipp Latzin; Anders Lindblad; Jessica E Pittman; Paul D Robinson; Margaret Rosenfeld; Florian Singer; Tim D Starner; Felix Ratjen; Wayne Morgan
Journal:  Ann Am Thorac Soc       Date:  2015-06

9.  Comprehensive integrated spirometry using raised volume passive and forced expirations and multiple-breath nitrogen washout in infants.

Authors:  Mohy G Morris
Journal:  Respir Physiol Neurobiol       Date:  2009-11-06       Impact factor: 1.931

10.  The effect of gas exchange on multiple-breath nitrogen washout measures of ventilation inhomogeneity in the mouse.

Authors:  Mahesh Dharmakumara; G Kim Prisk; Simon G Royce; Merryn Tawhai; Bruce R Thompson
Journal:  J Appl Physiol (1985)       Date:  2014-09-11