Literature DB >> 19897058

Comprehensive integrated spirometry using raised volume passive and forced expirations and multiple-breath nitrogen washout in infants.

Mohy G Morris1.   

Abstract

With the rapid somatic growth and development in infants, simultaneous accurate measurements of lung volume and airway function are essential. Raised volume rapid thoracoabdominal compression (RTC) is widely used to generate forced expiration from an airway opening pressure of 30 cmH(2)O (V(30)). The (dynamic) functional residual capacity (FRC(dyn)) remains the lung volume most routinely measured. The aim of this study was to develop comprehensive integrated spirometry that included all subdivisions of lung volume at V(30) or total lung capacity (TLC(30)). Measurements were performed on 17 healthy infants aged 8.6-119.7 weeks. A commercial system for multiple-breath nitrogen washout (MBNW) to measure lung volumes and a custom made system to perform RTC were used in unison. A refined automated raised volume RTC and the following two novel single maneuvers with dual volume measurements were performed from V(30) during a brief post-hyperventilation apneic pause: (1) the passive expiratory flow was integrated to produce the inspiratory capacity (IC) and the static (passive) FRC (FRC(st)) was estimated by initiating MBNW after end-passive expiration; (2) RTC was initiated late during passive expiration, flow was integrated to produce the slow vital capacity ((j)SVC) and the residual volume (RV) was measured by initiating MBNW after end-expiration while the jacket (j) was inflated. Intrasubject FRC(dyn) and FRC(st) measurements overlapped (p=0.6420) but neither did with the RV (p<0.0001). Means (95% confidence interval) of FRC(dyn), IC, FRC(st), (j)SVC, RV, forced vital capacity and tidal volume were 21.2 (19.7-22.7), 36.7 (33.0-40.4), 21.2 (19.6-22.8), 40.7 (37.2-44.2), 18.1 (16.6-19.7), 40.7 (37.1-44.2) and 10.2 (9.6-10.7)ml/kg, respectively. Static lung volumes and capacities at V(30) and variables from the best forced expiratory flow-volume curve were dependent on age, body length and weight. In conclusion, we developed a comprehensive physiologically integrated approach for in-depth investigation of lung function at V(30) in infants. Copyright 2009 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19897058      PMCID: PMC2858579          DOI: 10.1016/j.resp.2009.10.010

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  80 in total

1.  ATS/ERS statement: raised volume forced expirations in infants: guidelines for current practice.

Authors: 
Journal:  Am J Respir Crit Care Med       Date:  2005-12-01       Impact factor: 21.405

Review 2.  Developmental changes of pharyngeal airway patency: implications for pediatric anesthesia.

Authors:  Shiroh Isono
Journal:  Paediatr Anaesth       Date:  2006-02       Impact factor: 2.556

3.  Problems in the measurement of functional residual capacity.

Authors:  Simon J Broughton; Karl P Sylvester; Chloe M Page; Gerrard F Rafferty; Anthony D Milner; Anne Greenough
Journal:  Physiol Meas       Date:  2005-12-19       Impact factor: 2.833

4.  Standardizing lung function laboratories for multicenter trials.

Authors:  C S Beardsmore; J Y Paton; J R Thompson; A Laverty; C King; C Oliver; J Stocks
Journal:  Pediatr Pulmonol       Date:  2007-01

Review 5.  Lung function tests in neonates and infants with chronic lung disease of infancy: functional residual capacity.

Authors:  Georg Hülskamp; J Jane Pillow; Jürgen Dinger; Janet Stocks
Journal:  Pediatr Pulmonol       Date:  2006-01

Review 6.  Lung function tests in neonates and infants with chronic lung disease: forced expiratory maneuvers.

Authors:  Sooky Lum; Georg Hülskamp; Peter Merkus; Eugenio Baraldi; Ward Hofhuis; Janet Stocks
Journal:  Pediatr Pulmonol       Date:  2006-03

7.  Decrease of functional residual capacity and ventilation homogeneity after neuromuscular blockade in anesthetized young infants and preschool children.

Authors:  Britta S von Ungern-Sternberg; Jürg Hammer; Andreas Schibler; Franz J Frei; Thomas O Erb
Journal:  Anesthesiology       Date:  2006-10       Impact factor: 7.892

Review 8.  Lung function in infants and young children with chronic lung disease of infancy: the next steps?

Authors:  Janet Stocks; Allan Coates; Andrew Bush
Journal:  Pediatr Pulmonol       Date:  2007-01

Review 9.  The effects of antenatal smoking on lung function and respiratory symptoms in infants and children.

Authors:  Anthony D Milner; Harish Rao; Anne Greenough
Journal:  Early Hum Dev       Date:  2007-09-21       Impact factor: 2.079

10.  Effect of electronic compensation on plethysmographic airway resistance measurements.

Authors:  Simon Broughton; Gerrard F Rafferty; Anthony D Milner; Anne Greenough
Journal:  Pediatr Pulmonol       Date:  2007-09
View more
  1 in total

1.  Nasal versus oronasal raised volume forced expirations in infants--a real physiologic challenge.

Authors:  Mohy G Morris
Journal:  Pediatr Pulmonol       Date:  2012-02-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.