Christy L Haynes1, Lauren N Siff, R Mark Wightman.
Abstract
Statistical differences between amperometric traces recorded from chromaffin cells using K(+) and Ba(2+) secretagogues support the assertion that readily releasable pool (RRP) and reserve pool (RP) vesicles can be probed with pool-specific secretagogues. Release from the RRP was evoked by K(+) while release from the RP was evoked by Ba(2+). Similar temperature-dependent changes in spike area and half-width for both pools suggest that the content of RRP and RP vesicles is similar and packaged in the same way. Differences between the vesicle pools were revealed in the temperature dependence of spike frequency. While the burst spike frequency of the RRP, which is comprised of pre-docked and primed vesicles, increased 2.8% per degrees C, the RP spike frequency increased 12% per degrees C. This difference is attributed to a temperature-dependent mobilization of the RP. Furthermore, the RP exhibited more foot events at room temperature than the RRP but this difference was not apparent at 37 degrees C. This trend suggests that RP vesicle membranes have a compromised surface tension compared to RRP vesicles. Collectively, the changes of release characteristics with temperature reveal distinctions between the RRP and the RP.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17467077 PMCID: PMC2025685 DOI: 10.1016/j.bbamcr.2007.03.013
Source DB: PubMed Journal: Biochim Biophys Acta ISSN: 0006-3002