Literature DB >> 19515719

Intra-aortic balloon counterpulsation as a bridge to heart transplantation does not impair long-term survival.

Ola Gjesdal1, Einar Gude, Satish Arora, Torbjørn Leivestad, Arne K Andreassen, Lars Gullestad, Lars Aaberge, Harald Brunvand, Thor Edvardsen, Odd R Geiran, Svein Simonsen.   

Abstract

AIMS: There are few studies of the use of intra-aortic balloon pump (IABP) treatment as a bridge to heart transplantation (HTx). This is the first study to compare long-term clinical and haemodynamic outcomes in IABP-treated HTx patients and electively transplanted patients. METHODS AND
RESULTS: This was a retrospective study of all adult HTx recipients between 2001 and 2007. Thirty-two patients (aged 50 +/- 13 years) treated with IABP, as a bridge to HTx due to severe hypo-perfusion, were compared with 135 electively transplanted patients (aged 54 +/- 11 years). The mean time from onset of IABP to HTx was 21 +/- 16 days. Clinical condition improved during IABP treatment. Serum creatinine decreased from 128 +/- 56 to 102 +/- 29 micromol/L (P < 0.01), aspartate transaminase from 682 +/- 1299 to 63 +/- 89 U/L (P = 0.01), and ALAT from 483 +/- 867 to 126 +/- 284 U/L (P = 0.02). Intra-aortic balloon pump treatment related complications were few. Mortality was similar in the IABP and control groups at 30 days post-HTx (6.2 vs.3.7%, P = 0.54), at 1 year (9.4 vs.11.1%, P = 0.80), and beyond. Long-term clinical and haemodynamic indices were similar in the two groups.
CONCLUSION: Intra-aortic balloon pump treatment stabilizes patients in end-stage heart failure, is safe, well tolerated, and is successful in bridging acutely decompensated patients to transplantation. Complications are few and manageable. Following IABP and HTx, short- and long-term survival, biochemical and invasive and non-invasive haemodynamic outcomes were similar to those in electively transplanted patients.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19515719     DOI: 10.1093/eurjhf/hfp078

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  8 in total

1.  First-Line Support by Intra-Aortic Balloon Pump in Non-Ischaemic Cardiogenic Shock in the Era of Modern Ventricular Assist Devices.

Authors:  Corstiaan A den Uil; Giorgia Galli; Lucia S Jewbali; Kadir Caliskan; Olivier C Manintveld; Jasper J Brugts; Nicolas M van Mieghem; Mattie J Lenzen; Eric Boersma; Alina A Constantinescu
Journal:  Cardiology       Date:  2017-05-13       Impact factor: 1.869

Review 2.  Percutaneous Mechanical Circulatory Support Devices in Cardiogenic Shock.

Authors:  Aditya Mandawat; Sunil V Rao
Journal:  Circ Cardiovasc Interv       Date:  2017-05       Impact factor: 6.546

Review 3.  Continuous internal counterpulsation as a bridge to recovery in acute and chronic heart failure.

Authors:  Christos D Kontogiannis; Konstantinos Malliaras; Chris J Kapelios; Jay W Mason; John N Nanas
Journal:  World J Transplant       Date:  2016-03-24

4.  Effects of intra-aortic balloon pump counterpulsation on left ventricular mechanoenergetics in a porcine model of acute ischemic heart failure.

Authors:  Konstantinos Malliaras; Efstratios Charitos; Nikolaos Diakos; Iraklis Pozios; Apostolos Papalois; John Terrovitis; John Nanas
Journal:  J Cardiovasc Transl Res       Date:  2014-11-07       Impact factor: 4.132

5.  Intra-Aortic Balloon Pump Bridging to Heart Transplantation: Impact of the 2018 Allocation Change.

Authors:  Lauren V Huckaby; Laura M Seese; Michael A Mathier; Gavin W Hickey; Arman Kilic
Journal:  Circ Heart Fail       Date:  2020-08-06       Impact factor: 8.790

6.  Intra-aortic balloon pump (ΙΑΒΡ): from the old trends and studies to the current "extended" indications of its use.

Authors:  Haralabos Parissis; Alan Soo; Bassel Al-Alao
Journal:  J Cardiothorac Surg       Date:  2012-12-11       Impact factor: 1.637

Review 7.  Intra-aortic balloon pump counterpulsation (IABP) for myocardial infarction complicated by cardiogenic shock.

Authors:  Susanne Unverzagt; Michael Buerke; Antoinette de Waha; Johannes Haerting; Diana Pietzner; Melchior Seyfarth; Holger Thiele; Karl Werdan; Uwe Zeymer; Roland Prondzinsky
Journal:  Cochrane Database Syst Rev       Date:  2015-03-27

Review 8.  Mechanical Support in Early Cardiogenic Shock: What Is the Role of Intra-aortic Balloon Counterpulsation?

Authors:  Jesse R Kimman; Nicolas M Van Mieghem; Henrik Endeman; Jasper J Brugts; Alina A Constantinescu; Olivier C Manintveld; Eric A Dubois; Corstiaan A den Uil
Journal:  Curr Heart Fail Rep       Date:  2020-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.