Literature DB >> 19515328

[Intraocular pressure measurement in children].

H Bresson-Dumont1.   

Abstract

Intraocular pressure (IOP) measurement in children is often difficult to perform because younger children are non-compliant and resisting the examination. Normal IOP in children is not well established yet because in the studies reporting about IOP, the instruments used and clinical conditions have varied. Non contact tonometer often overestimates IOP in blinking children and is not always reliable. But all the others measurement techniques use contact (GAT, Perkins, Tono-Pen, ORA, RBT), and are not always suitable and easy-touse. Under general anaesthesia, mean IOP measured with Perkins applanation tonometer is under 8 mmHg before age of 3 months and under 12 mmHg between ages of 6 and 9 months. After, IOP shows an increasing trend with age of 1 mmHg per year up to 12 years. Some studies have proposed as normal pediatric IOP: To=0.71 x age (years) +10, up to age 10. Then, IOP tends to approach adult levels by 12 years of age. However pediatric glaucoma is rare: congenital glaucoma, before age of 3 years, autosomal dominant juvenile glaucoma, with family history of glaucoma and elevated IOP, or secondary glaucoma with special context. Thus, hypertony has to be confirmed by another measurement technique, correlated to central corneal thickness, and clinical examination (optic nerve head and visual field).

Entities:  

Mesh:

Year:  2009        PMID: 19515328     DOI: 10.1016/j.jfo.2009.03.008

Source DB:  PubMed          Journal:  J Fr Ophtalmol        ISSN: 0181-5512            Impact factor:   0.818


  3 in total

1.  Correlation analysis between central corneal thickness and intraocular pressure in juveniles in Northern China: the Jinan city eye study.

Authors:  Wen Wei; Zhaoshan Fan; Lihua Wang; Zhiwei Li; Wanzhen Jiao; Yun Li
Journal:  PLoS One       Date:  2014-08-22       Impact factor: 3.240

2.  A STROBE-compliant case-control study: Effects of cumulative doses of topical atropine on intraocular pressure and myopia progression.

Authors:  Teng-Chieh Yu; Tzu-En Wu; Yuan-Shen Wang; Shen-Fu Cheng; Shiow-Wen Liou
Journal:  Medicine (Baltimore)       Date:  2020-11-25       Impact factor: 1.889

3.  Possibilities of monitoring intraocular pressure in children using EASYTON transpalpebral tonometer.

Authors:  Elena N Iomdina; Nina Yu Kushnarevich
Journal:  Int Ophthalmol       Date:  2022-01-28       Impact factor: 2.029

  3 in total