Comparison of different pH measurement methods in meat.

O Mäki-Petäys1, H Korkeala, T Alanko, O Sorvettula.   

Abstract

The accuracy of portable pH meters and the nitrazine yellow method was compared with the reference method by determining the pH of 74 beef and 96 pork muscles. The pH was measured directly from the muscle. The results showed statistically significant differences (p less than 0.001) between the different electrometric combinations. Combinations of portable pH meters with puncture electrodes gave systematically higher pH values than the reference method. These differences were not very large but they may be of practical significance. The use of a piercing cover on the electrode to help the insertion of the electrode into the meat is not recommended, since it may cause a rise in pH values. Electrometric methods were found to be more precise than the nitrazine yellow method. On the basis of these findings there still is a need of further harmonization of the methods used for pH measurement of meat.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1950845      PMCID: PMC8127920     

Source DB:  PubMed          Journal:  Acta Vet Scand        ISSN: 0044-605X            Impact factor:   1.695


  4 in total

1.  Determination of pH in meat.

Authors:  H Korkeala; O Mäki-Petäys; T Alanko; O Sorvettula
Journal:  Meat Sci       Date:  1986       Impact factor: 5.209

2.  Comparison of chemical composition of meat determined at eight laboratories.

Authors:  E Dransfield; J C Casey; R Boccard; C Touraille; L Buchter; D E Hood; R L Joseph; I Schon; M Casteels; E Cosentino; B J Tinbergen
Journal:  Meat Sci       Date:  1983-02       Impact factor: 5.209

3.  The effect of the pH of meat on the boiling test.

Authors:  H Korkeala; T Alanko; O Mäki-Petäys; O Sorvettula
Journal:  Acta Vet Scand       Date:  1988       Impact factor: 1.695

4.  The relative precision of different methods of measuring pH in carcass muscles.

Authors:  F Bager; G V Petersen
Journal:  Nord Vet Med       Date:  1983-02
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.