Literature DB >> 19507794

Pentacam Scheimpflug quantitative imaging of the crystalline lens and intraocular lens.

Patricia Rosales1, Susana Marcos.   

Abstract

PURPOSE: To implement geometrical and optical distortion correction methods for anterior segment Scheimpflug images obtained with a commercially available system (Pentacam, Oculus Optikgeräte GmbH).
METHODS: Ray tracing algorithms were implemented to obtain corrected ocular surface geometry from the original images captured by the Pentacam's CCD camera. As details of the optical layout were not fully provided by the manufacturer, an iterative procedure (based on imaging of calibrated spheres) was developed to estimate the camera lens specifications. The correction procedure was tested on Scheimpflug images of a physical water cell model eye (with polymethylmethacrylate cornea and a commercial IOL of known dimensions) and of a normal human eye previously measured with a corrected optical and geometrical distortion Scheimpflug camera (Topcon SL-45 [Topcon Medical Systems Inc] from the Vrije University, Amsterdam, Holland).
RESULTS: Uncorrected Scheimpflug images show flatter surfaces and thinner lenses than in reality. The application of geometrical and optical distortion correction algorithms improves the accuracy of the estimated anterior lens radii of curvature by 30% to 40% and of the estimated posterior lens by 50% to 100%. The average error in the retrieved radii was 0.37 and 0.46 mm for the anterior and posterior lens radii of curvature, respectively, and 0.048 mm for lens thickness.
CONCLUSIONS: The Pentacam Scheimpflug system can be used to obtain quantitative information on the geometry of the crystalline lens, provided that geometrical and optical distortion correction algorithms are applied, within the accuracy of state-of-the art phakometry and biometry. The techniques could improve with exact knowledge of the technical specifications of the instrument, improved edge detection algorithms, consideration of aspheric and non-rotationally symmetrical surfaces, and introduction of a crystalline gradient index.

Entities:  

Mesh:

Year:  2009        PMID: 19507794     DOI: 10.3928/1081597X-20090422-04

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  24 in total

1.  OCT-based crystalline lens topography in accommodating eyes.

Authors:  Pablo Pérez-Merino; Miriam Velasco-Ocana; Eduardo Martinez-Enriquez; Susana Marcos
Journal:  Biomed Opt Express       Date:  2015-11-24       Impact factor: 3.732

2.  System for on- and off-axis volumetric OCT imaging and ray tracing aberrometry of the crystalline lens.

Authors:  Marco Ruggeri; Siobhan Williams; Bianca Maceo Heilman; Yue Yao; Yu-Cherng Chang; Ashik Mohamed; N Geetha Sravani; Heather Durkee; Cornelis Rowaan; Alex Gonzalez; Arthur Ho; Jean-Marie Parel; Fabrice Manns
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

3.  Ultrahigh-resolution OCT imaging of the human cornea.

Authors:  René M Werkmeister; Sabina Sapeta; Doreen Schmidl; Gerhard Garhöfer; Gerald Schmidinger; Valentin Aranha Dos Santos; Gerold C Aschinger; Isabella Baumgartner; Niklas Pircher; Florian Schwarzhans; Anca Pantalon; Harminder Dua; Leopold Schmetterer
Journal:  Biomed Opt Express       Date:  2017-01-30       Impact factor: 3.732

4.  Three-dimensional visualization of opacifications in the murine crystalline lens by in vivo optical coherence tomography.

Authors:  Pablo Eugui; Danielle J Harper; Stefan Kummer; Antonia Lichtenegger; Johanna Gesperger; Tanja Himmel; Marco Augustin; Conrad W Merkle; Martin Glösmann; Bernhard Baumann
Journal:  Biomed Opt Express       Date:  2020-03-19       Impact factor: 3.732

5.  Morphological changes of human crystalline lens in myopia.

Authors:  Geethika Muralidharan; Eduardo Martínez-Enríquez; Judith Birkenfeld; Miriam Velasco-Ocana; Pablo Pérez-Merino; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-11-05       Impact factor: 3.732

6.  Distortion correction of OCT images of the crystalline lens: gradient index approach.

Authors:  Damian Siedlecki; Alberto de Castro; Enrique Gambra; Sergio Ortiz; David Borja; Stephen Uhlhorn; Fabrice Manns; Susana Marcos; Jean-Marie Parel
Journal:  Optom Vis Sci       Date:  2012-05       Impact factor: 1.973

7.  Repeated measurements of the anterior segment during accommodation using long scan depth optical coherence tomography.

Authors:  Yimin Yuan; Feng Chen; Meixiao Shen; Fan Lu; Jianhua Wang
Journal:  Eye Contact Lens       Date:  2012-03       Impact factor: 2.018

8.  Biomass stoves and lens opacity and cataract in Nepalese women.

Authors:  Amod K Pokhrel; Michael N Bates; Sachet P Shrestha; Ian L Bailey; Robert B Dimartino; Kirk R Smith
Journal:  Optom Vis Sci       Date:  2013-03       Impact factor: 1.973

9.  Off-axis optical coherence tomography imaging of the crystalline lens to reconstruct the gradient refractive index using optical methods.

Authors:  Alberto de Castro; Judith Birkenfeld; Bianca Maceo Heilman; Marco Ruggeri; Esdras Arrieta; Jean-Marie Parel; Fabrice Manns; Susana Marcos
Journal:  Biomed Opt Express       Date:  2019-06-26       Impact factor: 3.732

10.  Volumetric macro- and micro-scale assessment of crystalline lens opacities in cataract patients using long-depth-range swept source optical coherence tomography.

Authors:  Ireneusz Grulkowski; Silvestre Manzanera; Lukasz Cwiklinski; Juan Mompeán; Alberto de Castro; Jose Maria Marin; Pablo Artal
Journal:  Biomed Opt Express       Date:  2018-07-24       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.