Literature DB >> 1950494

Bone mass distribution in the lower leg. A quantitative computed tomographic study of 36 individuals.

A Alho1, A Høiseth.   

Abstract

We measured bone density and volume at different levels of the normal lower leg by computed tomography. The fibular mass at each transverse level was 18-20 percent of the total bone mass. Tibial masses at all the levels correlated with distal femoral and proximal tibial masses. Summing the fibular and tibial masses augmented the correlations. The mass values varied substantially at different levels of the lower leg, being highest in the midshaft. We hypothesize that the lower extremity is a biomechanical continuum where the distribution of the bone mass corresponds to the functional demands, indicating that the fibula is not "dispensable."

Mesh:

Year:  1991        PMID: 1950494     DOI: 10.3109/17453679108996647

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  8 in total

1.  Accuracy and the influence of marrow fat on quantitative CT and dual-energy X-ray absorptiometry measurements of the femoral neck in vitro.

Authors:  J W Kuiper; C van Kuijk; J L Grashuis; A G Ederveen; H E Schütte
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

2.  Meagre effects of disuse on the human fibula are not explained by bone size or geometry.

Authors:  A Ireland; R F Capozza; G R Cointry; L Nocciolino; J L Ferretti; J Rittweger
Journal:  Osteoporos Int       Date:  2016-10-12       Impact factor: 4.507

3.  Pairwise strength relationships of cortical and cancellous bone in human femur: an autopsy study.

Authors:  A Alho; K Strømsøe; A Høiseth
Journal:  Arch Orthop Trauma Surg       Date:  1995       Impact factor: 3.067

4.  Temporal Changes in Reverse Torque of Locking-Head Screws Used in the Locking Plate in Segmental Tibial Defect in Goat Model.

Authors:  Remigiusz M Grzeskowiak; Rebecca E Rifkin; Elizabeth G Croy; Richard C Steiner; Reza Seddighi; Pierre-Yves Mulon; Henry S Adair; David E Anderson
Journal:  Front Surg       Date:  2021-04-27

5.  Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model.

Authors:  Remigiusz M Grzeskowiak; Carrie Wheeler; Elizabeth Taylor; James Lillich; James Roush; Alexandru S Biris; David E Anderson
Journal:  BMC Vet Res       Date:  2019-09-05       Impact factor: 2.741

6.  Fibula response to disuse: a longitudinal analysis in people with spinal cord injury.

Authors:  Shima Abdelrahman; Mariel Purcell; Timo Rantalainen; Sylvie Coupaud; Alex Ireland
Journal:  Arch Osteoporos       Date:  2022-03-19       Impact factor: 2.879

7.  Bone marrow oedema predicts bone collapse in paediatric and adolescent leukaemia patients with corticosteroid-induced osteonecrosis.

Authors:  Ashok Joseph Theruvath; Preeti Arun Sukerkar; Shanshan Bao; Jarrett Rosenberg; Sandra Luna-Fineman; Sandhya Kharbanda; Heike Elisabeth Daldrup-Link
Journal:  Eur Radiol       Date:  2017-07-19       Impact factor: 5.315

8.  Effect of cyclic loading on the stability of screws placed in the locking plates used to bridge segmental bone defects.

Authors:  Remigiusz M Grzeskowiak; Laura R Freeman; David P Harper; David E Anderson; Pierre-Yves Mulon
Journal:  J Orthop Res       Date:  2020-09-09       Impact factor: 3.494

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.