Literature DB >> 19500527

Performance evaluation of the automated NucliSens easyMAG nucleic acid extraction platform in comparison with QIAamp Mini kit from clinical specimens.

Francesca Perandin1, Patrizia C Pollara, Franco Gargiulo, Carlo Bonfanti, Nino Manca.   

Abstract

The performance of the NucliSens easyMAG platform for the extraction of nucleic acid from different clinical specimens was compared with a manual procedure. A total of 308 specimens were analyzed: 209 plasma samples collected for virus detection and quantification of cytomegalovirus (CMV) and Epstein-Barr virus (EBV) (n = 70), and 29 for HIV genotyping for drug resistance. Linearity of extraction was tested on dilution series of CMV and EBV; the correlation coefficient (R(2)) for standard curves based on repeated extraction runs was 0.99 for CMV and EBV. Inter- and intrarun variability was in accordance with previous studies, and the correlation between automated and manual extraction was very high. The concordant results were 95.7% for CMV and 100% for EBV. The results of sequence analysis for HIV drug resistance showed a concordance in 24 of 29 specimens. The NucliSens easyMAG is extremely easy to perform, is automated, and resulted in a strong reduction of hands-on time compared with manual protocol.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19500527     DOI: 10.1016/j.diagmicrobio.2009.02.013

Source DB:  PubMed          Journal:  Diagn Microbiol Infect Dis        ISSN: 0732-8893            Impact factor:   2.803


  9 in total

1.  Optimization of Toxoplasma gondii DNA extraction from amniotic fluid using NucliSENS easyMAG and comparison with QIAamp DNA minikit.

Authors:  B Faucher; F Miermont; S Ranque; J Franck; R Piarroux
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-09-04       Impact factor: 3.267

Review 2.  Updated values for molecular diagnosis for highly pathogenic avian influenza virus.

Authors:  Akira Sakurai; Futoshi Shibasaki
Journal:  Viruses       Date:  2012-08-07       Impact factor: 5.048

3.  Epidemiological and Evolutionary Dynamics of Influenza B Viruses in Malaysia, 2012-2014.

Authors:  Xiang Yong Oong; Kim Tien Ng; Tommy Tsan-Yuk Lam; Yong Kek Pang; Kok Gan Chan; Nik Sherina Hanafi; Adeeba Kamarulzaman; Kok Keng Tee
Journal:  PLoS One       Date:  2015-08-27       Impact factor: 3.240

4.  Inter-laboratory assessment of different digital PCR platforms for quantification of human cytomegalovirus DNA.

Authors:  Jernej Pavšič; Alison Devonshire; Andrej Blejec; Carole A Foy; Fran Van Heuverswyn; Gerwyn M Jones; Heinz Schimmel; Jana Žel; Jim F Huggett; Nicholas Redshaw; Maria Karczmarczyk; Erkan Mozioğlu; Sema Akyürek; Müslüm Akgöz; Mojca Milavec
Journal:  Anal Bioanal Chem       Date:  2017-01-26       Impact factor: 4.142

5.  Comparison of the new fully automated extraction platform eMAG to the MagNA PURE 96 and the well-established easyMAG for detection of common human respiratory viruses.

Authors:  Musa Hindiyeh; Orna Mor; Rakefet Pando; Batya Mannasse; Areej Kabat; Hadar Assraf-Zarfati; Ella Mendelson; Danit Sofer; Michal Mandelboim
Journal:  PLoS One       Date:  2019-02-19       Impact factor: 3.240

6.  Comparison of eMAG™ versus NucliSENS® EasyMAG® performance on clinical specimens.

Authors:  Magali Garcia; Céline Chessa; Anne Bourgoin; Geneviève Giraudeau; Chloé Plouzeau; Gérard Agius; Nicolas Lévêque; Agnès Beby-Defaux
Journal:  J Clin Virol       Date:  2017-01-29       Impact factor: 3.168

7.  The effects of age on clinical characteristics, hospitalization and mortality of patients with influenza-related illness at a tertiary care centre in Malaysia.

Authors:  Pui Li Wong; Hoe Leong Sii; Chun Keat P'ng; Soon Sean Ee; Xiang Yong Oong; Kim Tien Ng; Nik Sherina Hanafi; Kok Keng Tee; Maw Pin Tan
Journal:  Influenza Other Respir Viruses       Date:  2020-02-05       Impact factor: 4.380

8.  Prospective evaluation of a new automated nucleic acid extraction system using routine clinical respiratory specimens.

Authors:  C Mengelle; J-M Mansuy; K Sandres-Sauné; C Barthe; J Boineau; J Izopet
Journal:  J Med Virol       Date:  2012-06       Impact factor: 2.327

9.  Quantitative detection of epstein-barr virus DNA in cerebrospinal fluid and blood samples of patients with relapsing-remitting multiple sclerosis.

Authors:  Clementina E Cocuzza; Fabrizio Piazza; Rosario Musumeci; Davide Oggioni; Simona Andreoni; Margherita Gardinetti; Letizia Fusco; Maura Frigo; Paola Banfi; Maria R Rottoli; Paolo Confalonieri; Monica Rezzonico; Maria T Ferrò; Guido Cavaletti
Journal:  PLoS One       Date:  2014-04-10       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.