Literature DB >> 19494424

In-beam PET monitoring of mono-energetic (16)O and (12)C beams: experiments and FLUKA simulations for homogeneous targets.

F Sommerer1, F Cerutti, K Parodi, A Ferrari, W Enghardt, H Aiginger.   

Abstract

(16)O and (12)C ion beams will be used-besides lighter ions-for cancer treatment at the Heidelberg Ion Therapy Center (HIT), Germany. It is planned to monitor the treatment by means of in-beam positron emission tomography (PET) as it is done for therapy with (12)C beams at the experimental facility at the Gesellschaft für Schwerionenforschung (GSI), Darmstadt, Germany. To enable PET also for (16)O beams, experimental data of the beta(+)-activity created by these beams are needed. Therefore, in-beam PET measurements of the activity created by (16)O beams of various energies on targets of PMMA, water and graphite were performed at GSI for the first time. Additionally reference measurements of (12)C beams on the same target materials were done. The results of the measurements are presented. The deduction of clinically relevant results from in-beam PET data requires reliable simulations of the beta(+)-activity production, which is done presently by a dedicated code limited to (12)C beams. Because this code is not extendable to other ions in an easy way, a new code, capable of simulating the production of the beta(+)-activity by all ions of interest, is needed. Our choice is the general purpose Monte Carlo code FLUKA which was used to simulate the ion transport, the beta(+)-active isotope production, the decay, the positron annihilation and the transport of the annihilation photons. The detector response was simulated with an established software that gives the output in the same list-mode data format as in the experiment. This allows us to use the same software to reconstruct measured and simulated data, which makes comparisons easier and more reliable. The calculated activity distribution shows general good agreement with the measurements.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19494424     DOI: 10.1088/0031-9155/54/13/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

Review 1.  Positron emission tomography imaging approaches for external beam radiation therapies: current status and future developments.

Authors:  P M Price; M M Green
Journal:  Br J Radiol       Date:  2011-03-22       Impact factor: 3.039

2.  TOPAS: an innovative proton Monte Carlo platform for research and clinical applications.

Authors:  J Perl; J Shin; J Schumann; B Faddegon; H Paganetti
Journal:  Med Phys       Date:  2012-11       Impact factor: 4.071

Review 3.  Monte Carlo Simulations of Particle Interactions with Tissue in Carbon Ion Therapy.

Authors:  George Dedes; Katia Parodi
Journal:  Int J Part Ther       Date:  2016-02-09

4.  Radioactive Beams for Image-Guided Particle Therapy: The BARB Experiment at GSI.

Authors:  Daria Boscolo; Daria Kostyleva; Mohammad Javad Safari; Vasiliki Anagnostatou; Juha Äystö; Soumya Bagchi; Tim Binder; Georgios Dedes; Peter Dendooven; Timo Dickel; Vasyl Drozd; Bernhard Franczack; Hans Geissel; Chiara Gianoli; Christian Graeff; Tuomas Grahn; Florian Greiner; Emma Haettner; Roghieh Haghani; Muhsin N Harakeh; Felix Horst; Christine Hornung; Jan-Paul Hucka; Nasser Kalantar-Nayestanaki; Erika Kazantseva; Birgit Kindler; Ronja Knöbel; Natalia Kuzminchuk-Feuerstein; Bettina Lommel; Ivan Mukha; Chiara Nociforo; Shunki Ishikawa; Giulio Lovatti; Munetaka Nitta; Ikechi Ozoemelam; Stephane Pietri; Wolfgang R Plaß; Andrej Prochazka; Sivaji Purushothaman; Claire-Anne Reidel; Heidi Roesch; Fabio Schirru; Christoph Schuy; Olga Sokol; Timo Steinsberger; Yoshiki K Tanaka; Isao Tanihata; Peter Thirolf; Walter Tinganelli; Bernd Voss; Uli Weber; Helmut Weick; John S Winfield; Martin Winkler; Jianwei Zhao; Christoph Scheidenberger; Katia Parodi; Marco Durante
Journal:  Front Oncol       Date:  2021-08-19       Impact factor: 5.738

5.  Monitoring of patients treated with particle therapy using positron-emission-tomography (PET): the MIRANDA study.

Authors:  Stephanie E Combs; Julia Bauer; Daniel Unholtz; Christopher Kurz; Thomas Welzel; Daniel Habermehl; Thomas Haberer; Jürgen Debus; Katia Parodi
Journal:  BMC Cancer       Date:  2012-04-03       Impact factor: 4.430

Review 6.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

7.  The FLUKA Code: An Accurate Simulation Tool for Particle Therapy.

Authors:  Giuseppe Battistoni; Julia Bauer; Till T Boehlen; Francesco Cerutti; Mary P W Chin; Ricardo Dos Santos Augusto; Alfredo Ferrari; Pablo G Ortega; Wioletta Kozłowska; Giuseppe Magro; Andrea Mairani; Katia Parodi; Paola R Sala; Philippe Schoofs; Thomas Tessonnier; Vasilis Vlachoudis
Journal:  Front Oncol       Date:  2016-05-11       Impact factor: 6.244

Review 8.  Range Verification Methods in Particle Therapy: Underlying Physics and Monte Carlo Modeling.

Authors:  Aafke Christine Kraan
Journal:  Front Oncol       Date:  2015-07-07       Impact factor: 6.244

9.  Radioactive Beams in Particle Therapy: Past, Present, and Future.

Authors:  Marco Durante; Katia Parodi
Journal:  Front Phys       Date:  2020-08-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.