Literature DB >> 19493652

Delamination and adhesive wear behavior of alpha-tocopherol-stabilized irradiated ultrahigh-molecular-weight polyethylene.

Keith K Wannomae1, Steven D Christensen, Brad R Micheli, Shannon L Rowell, Dave W Schroeder, Orhun K Muratoglu.   

Abstract

Wear and delamination of conventional ultrahigh-molecular-weight polyethylene (UHMWPE) components used in total knee arthroplasty can compromise long-term performance. Radiation cross-linking and melt-annealing reduced wear and increased delamination resistance of UHMWPE. An alternative material is the alpha-tocopherol-stabilized irradiated UHMWPE (alphaTPE), with improved mechanical and fatigue properties vs irradiated and melted UHMWPE. We studied the wear and delamination resistance of alphaTPE and conventional UHMWPE (direct compression molded GUR 1050 and Himont 1900) under reciprocating unidirectional motion. Wear resistance was improved, and no delamination was observed in alphaTPE. Accelerated aging did not alter the wear and delamination behavior of alphaTPE. The GUR 1050 UHMWPE showed delamination and pitting when subjected to unidirectional reciprocating motion after accelerated aging. Himont 1900 UHMWPE showed no delamination when subjected to unidirectional reciprocating motion after accelerated aging. alpha-Tocopherol-stabilized irradiated UHMWPE is advanced for use in total knee arthroplasty due to its high resistance to wear, delamination, and oxidation. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19493652     DOI: 10.1016/j.arth.2009.04.005

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Vitamin E-enriched polyethylene bearings are not inferior to Arcom bearings in primary total knee arthroplasty at medium-term follow-up.

Authors:  Samy Ftaita; Aurélie Vanden Berghe; Emmanuel Thienpont
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-08       Impact factor: 3.067

Review 2.  Effectiveness of Vitamin-E-Doped Polyethylene in Joint Replacement: A Literature Review.

Authors:  Antonio Gigante; Carlo Bottegoni; Vincenza Ragone; Lorenzo Banci
Journal:  J Funct Biomater       Date:  2015-09-08

3.  Analysis of wear, wear particles, and reduced inflammatory potential of vitamin E ultrahigh-molecular-weight polyethylene for use in total joint replacement.

Authors:  C L Bladen; S Teramura; S L Russell; K Fujiwara; J Fisher; E Ingham; N Tomita; J L Tipper
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

4.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

5.  Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator.

Authors:  Saverio Affatato; Alessandro Ruggiero; Sami Abdel Jaber; Massimiliano Merola; Pierangiola Bracco
Journal:  Materials (Basel)       Date:  2018-03-16       Impact factor: 3.623

  5 in total