Literature DB >> 19493155

Safe and rapid isolation of pulmonary veins using a novel circular ablation catheter and duty-cycled RF generator.

Sabine Fredersdorf1, Stefan Weber, Clemens Jilek, Norbert Heinicke, Christian VON Bary, Carsten Jungbauer, Günter A Riegger, Okka W Hamer, Andreas Jeron.   

Abstract

BACKGROUND: Ablation of atrial fibrillation (AF) has been one of the most difficult and time-consuming electrophysiological procedures. Due to the rapidly increasing demand for ablation procedures, technical advances would be helpful to reduce complexity and procedure time in AF ablation. Therefore, we investigated the feasibility of a single-catheter technique for pulmonary vein (PV) isolation utilizing a decapolar catheter combined with a duty-cycled, unipolar-bipolar radiofrequency (RF) generator.
METHODS: AF mapping and ablation was performed in 21 consecutive patients (mean age 59 +/- 12 years, 9 males) with paroxysmal AF (n = 17) and persistent AF (n = 4). The ablation catheter was forwarded to the LA via single-transseptal puncture. All electrodes were energized in 2 to 5 applications per vein, followed by segmental RF applications, as needed, to achieve electrical isolation. To assess left atrial anatomy for purposes of catheter manipulation, and later evaluate the possibility of asymptomatic PV-stenosis, CT or MR imaging was performed both prior to ablation and at 6-month follow-up.
RESULTS: Isolation could be achieved in 85/86 veins (99%). Procedure time for ablation was 81 +/- 13 minutes, and fluoroscopy time was 30 +/- 11 minutes. There were no procedural complications. Success rate at 6 months was 86% (18/21). MR or CT imaging excluded asymptomatic PV-stenosis.
CONCLUSION: Mapping and ablation of PVs can be performed in a safe and efficient manner using a single-catheter technique, with short procedure times and minimal learning curve. Thus, this system may be of high interest not only for high volume but all centers performing AF ablation.

Entities:  

Mesh:

Year:  2009        PMID: 19493155     DOI: 10.1111/j.1540-8167.2009.01501.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  13 in total

Review 1.  State-of-the-art and emerging technologies for atrial fibrillation ablation.

Authors:  Jane Dewire; Hugh Calkins
Journal:  Nat Rev Cardiol       Date:  2010-03       Impact factor: 32.419

Review 2.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

3.  Silent cerebral events as a result of left atrial catheter ablation do not cause neuropsychological sequelae--a MRI-controlled multicenter study.

Authors:  Christian von Bary; Thomas Deneke; Thomas Arentz; Anja Schade; Heiko Lehrmann; Christoph Eissnert; Susanne Schwab-Malek; Sabine Fredersdorf; Ekrem Ücer; Dobri Baldaranov; Christina Wendl; Felix Schlachetzki
Journal:  J Interv Card Electrophysiol       Date:  2015-04-29       Impact factor: 1.900

Review 4.  Comparison of the Efficacy of PVAC® and nMARQ for paroxysmal atrial fibrillation.

Authors:  Avishag Laish-Farkash; Mahmoud Suleiman
Journal:  J Atr Fibrillation       Date:  2017-04-30

5.  Clinical outcomes of AF patients treated with the first and second-generation of circular mapping and ablation catheter: insights from a real world multicenter experience.

Authors:  Giovanni Rovaris; Paolo De Filippo; Francesco Laurenzi; Gabriele Zanotto; Nicola Bottoni; Mattia Pozzi; Fabrizio Giofrè; Piergiuseppe De Girolamo; Emanuela Visentin; Elena Piazzi; Paola Ferrari
Journal:  J Interv Card Electrophysiol       Date:  2017-09-05       Impact factor: 1.900

6.  First results and follow-up of a second-generation circular mapping and ablation catheter.

Authors:  Stefan Weber; Martin Höher; Dominik Schultes
Journal:  J Interv Card Electrophysiol       Date:  2016-05-26       Impact factor: 1.900

7.  Comparison of PV signal quality using a novel circular mapping and ablation catheter versus a standard circular mapping catheter.

Authors:  Christian von Bary; Sabine Fredersdorf-Hahn; Norbert Heinicke; Carsten Jungbauer; Peter Schmid; Günter A Riegger; Stefan Weber
Journal:  J Interv Card Electrophysiol       Date:  2011-02-12       Impact factor: 1.900

Review 8.  Prevention of esophageal thermal injury during radiofrequency ablation for atrial fibrillation.

Authors:  Enzhao Liu; Michael Shehata; Tong Liu; Allen Amorn; Eugenio Cingolani; Vinod Kannarkat; Sumeet S Chugh; Xunzhang Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-06-21       Impact factor: 1.900

9.  Long-term outcomes (>2 years) of atrial fibrillation ablation using a multi-electrode ablation catheter in patients with paroxysmal atrial fibrillation.

Authors:  Khang-Li Looi; Parag Gajendragadkar; Tamer Taha; Maros Elsik; Elizabeth Scully; Patrick Heck; Simon Fynn; Munmohan Virdee; David Begley
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

10.  Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results.

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Martin Brueck; Dirk Bandorski; Elvan Akin; Ali Reza Salili
Journal:  J Interv Card Electrophysiol       Date:  2010-01       Impact factor: 1.900

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.