Literature DB >> 19937098

Pulmonary vein isolation by duty-cycled bipolar and unipolar antrum ablation using a novel multielectrode ablation catheter system: first clinical results.

Marcus Wieczorek1, Reinhard Hoeltgen, Martin Brueck, Dirk Bandorski, Elvan Akin, Ali Reza Salili.   

Abstract

BACKGROUND: The electrical disconnection of the pulmonary veins (PV) plays an important role in the ablation strategy of paroxysmal atrial fibrillation (PAF). Circumferential antral ablation with a conventional ablation technique using a steerable ablation catheter is sometimes difficult to perform and does not always result in isolation of the targeted PV.
METHODS: Patients with symptomatic PAF were treated with a novel circular mapping/ablation catheter (PVAC). Ablation was performed in the antral region of the PV with a power-modulated bipolar/unipolar RF generator using 8-10 W until isolation of the vein was achieved. Seven-day Holter monitor recordings were performed off antiarrhythmic drugs at 3 and 6 months after the initial procedure. A subgroup of patients had received an implantable recorder before ablation, and the device was interrogated at the same time. The primary objective of this study is acute isolation of the targeted PV, and the second objective is clinical efficacy with a short-term follow-up.
RESULTS: In 73 patients, 290 PV could be reached with the PVAC. Antral ablation was performed in 244 PV showing PV potentials. Acutely, 243 PV (99%) were isolated with the PVAC after 21+/-7 energy applications per patient with a mean fluoroscopy time of 20+/-11 min. Total procedure time was 122+/-27 min. No complications were observed. Follow-up at 3 and 6 months showed freedom from AF in 61 of 73 (84%) patients and 38 of 45 patients (85%), respectively, off antiarrhythmic drugs.
CONCLUSIONS: PV isolation by duty-cycled unipolar/bipolar RF ablation can be effectively and safely performed with a circular, decapolar catheter. Clinical results at 3 and 6 months after ablation are encouraging with the need for longer follow-up intervals.

Entities:  

Mesh:

Year:  2010        PMID: 19937098     DOI: 10.1007/s10840-009-9446-z

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  28 in total

1.  Effects of circumferential ostial radiofrequency lesions on pulmonary vein activation recorded with a multipolar basket catheter.

Authors:  Thomas Arentz; Jörg Von Rosenthal; Reinhold Weber; Gerd Bürkle; Thomas Blum; Jochem Stockinger; Franz Josef Neumann; Dietrich Kalusche
Journal:  J Cardiovasc Electrophysiol       Date:  2005-03

2.  Worldwide survey on the methods, efficacy, and safety of catheter ablation for human atrial fibrillation.

Authors:  Riccardo Cappato; Hugh Calkins; Shih-Ann Chen; Wyn Davies; Yoshito Iesaka; Jonathan Kalman; You-Ho Kim; George Klein; Douglas Packer; Allan Skanes
Journal:  Circulation       Date:  2005-02-21       Impact factor: 29.690

3.  Circumferential ultrasound ablation for pulmonary vein isolation: analysis of acute and chronic failures.

Authors:  Walid Saliba; David Wilber; Douglas Packer; Nassir Marrouche; Robert Schweikert; Ennio Pisano; Jeannie Shewchik; Dianna Bash; Raffaele Fanelli; Domenico Potenza; Pietro Santarelli; Patrick Tchou; Andrea Natale
Journal:  J Cardiovasc Electrophysiol       Date:  2002-10

4.  Prevalence of pulmonary vein disconnection after anatomical ablation for atrial fibrillation: consequences of wide atrial encircling of the pulmonary veins.

Authors:  Mélèze Hocini; Prashanthan Sanders; Pierre Jaïs; Li-Fern Hsu; Rukshen Weerasoriya; Christophe Scavée; Yoshihide Takahashi; Martin Rotter; Florence Raybaud; Laurent Macle; Jacques Clémenty; Michel Haïssaguerre
Journal:  Eur Heart J       Date:  2005-01-06       Impact factor: 29.983

5.  A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: a single-catheter approach to pulmonary vein antrum isolation.

Authors:  Mauricio S Arruda; Ding Sheng He; Paul Friedman; Hiroshi Nakagawa; Charles Bruce; Koji Azegami; Robert Anders; Peter Kozel; Amedeo Chiavetta; Paul Marad; David MacAdam; Warren Jackman; David J Wilber
Journal:  J Cardiovasc Electrophysiol       Date:  2007-02

6.  Electrophysiologically guided pulmonary vein isolation during sustained atrial fibrillation.

Authors:  Laurent Macle; Pierre Jaïs; Christophe Scavée; Rukshen Weerasooriya; Dipen C Shah; Mélèze Hocini; Kee-Joon Choi; Florence Raybaud; Jacques Clémenty; Michel Haïssaguerre
Journal:  J Cardiovasc Electrophysiol       Date:  2003-03

7.  First human experience with pulmonary vein isolation using a through-the-balloon circumferential ultrasound ablation system for recurrent atrial fibrillation.

Authors:  A Natale; E Pisano; J Shewchik; D Bash; R Fanelli; D Potenza; P Santarelli; R Schweikert; R White; W Saliba; L Kanagaratnam; P Tchou; M Lesh
Journal:  Circulation       Date:  2000-10-17       Impact factor: 29.690

8.  Percutaneous pulmonary vein cryoablation to treat atrial fibrillation.

Authors:  Tom Wong; Vias Markides; Nicholas S Peters; D Wyn Davies
Journal:  J Interv Card Electrophysiol       Date:  2004-10       Impact factor: 1.900

9.  Pulmonary vein potentials in patients with and without atrial fibrillation.

Authors:  Eva Hertervig; Ole Kongstad; Erik Ljungstrom; Bertil Olsson; Shiwen Yuan
Journal:  Europace       Date:  2008-04-17       Impact factor: 5.214

10.  Complete isolation of left atrium surrounding the pulmonary veins: new insights from the double-Lasso technique in paroxysmal atrial fibrillation.

Authors:  Feifan Ouyang; Dietmar Bänsch; Sabine Ernst; Anselm Schaumann; Hitoshi Hachiya; Minglong Chen; Julian Chun; Peter Falk; Afsaneh Khanedani; Matthias Antz; Karl-Heinz Kuck
Journal:  Circulation       Date:  2004-10-04       Impact factor: 29.690

View more
  13 in total

Review 1.  Multi-Electrode Ablation Catheters for AF Ablation: Effective Reality or Elegant Experiment?

Authors:  Lucas Boersma
Journal:  J Atr Fibrillation       Date:  2012-06-15

2.  Safety and Feasibility of Contrast Injection During Pulmonary Vein Isolation with the nMARQ™ Multi-Electrode Catheter.

Authors:  Avishag Laish Farkash; Amos Katz; Ornit Cohen; Evgeny Fishman; Chaim Yosefy; Vladimir Khalameizer
Journal:  J Atr Fibrillation       Date:  2015-12-31

Review 3.  Comparison of the Efficacy of PVAC® and nMARQ for paroxysmal atrial fibrillation.

Authors:  Avishag Laish-Farkash; Mahmoud Suleiman
Journal:  J Atr Fibrillation       Date:  2017-04-30

4.  Comparison of PV signal quality using a novel circular mapping and ablation catheter versus a standard circular mapping catheter.

Authors:  Christian von Bary; Sabine Fredersdorf-Hahn; Norbert Heinicke; Carsten Jungbauer; Peter Schmid; Günter A Riegger; Stefan Weber
Journal:  J Interv Card Electrophysiol       Date:  2011-02-12       Impact factor: 1.900

Review 5.  Prevention of esophageal thermal injury during radiofrequency ablation for atrial fibrillation.

Authors:  Enzhao Liu; Michael Shehata; Tong Liu; Allen Amorn; Eugenio Cingolani; Vinod Kannarkat; Sumeet S Chugh; Xunzhang Wang
Journal:  J Interv Card Electrophysiol       Date:  2012-06-21       Impact factor: 1.900

6.  Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation.

Authors:  Rypko J Beukema; Arif Elvan; Jaap Jan J Smit; Peter Paul H M Delnoy; Anand R Ramdat Misier; Vivek Reddy
Journal:  J Interv Card Electrophysiol       Date:  2012-02-23       Impact factor: 1.900

7.  Pulmonary vein re-isolation for atrial fibrillation using duty-cycled phased radiofrequency ablation: safety and efficacy of a primary 2:1 bipolar/unipolar ablation mode.

Authors:  Marcus Wieczorek; Reinhard Hoeltgen; Shahram Tajtaraghi; Wolfgang Lawrenz; Michael Lukat
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

8.  Long-term outcomes (>2 years) of atrial fibrillation ablation using a multi-electrode ablation catheter in patients with paroxysmal atrial fibrillation.

Authors:  Khang-Li Looi; Parag Gajendragadkar; Tamer Taha; Maros Elsik; Elizabeth Scully; Patrick Heck; Simon Fynn; Munmohan Virdee; David Begley
Journal:  J Interv Card Electrophysiol       Date:  2012-10-25       Impact factor: 1.900

Review 9.  Phased RF Ablation: Results and Concerns.

Authors:  Alexandra Kiss; Gábor Sándorfi; Edina Nagy-Baló; Mihran Martirosyan; Zoltan Csanadi
Journal:  J Atr Fibrillation       Date:  2015-06-30

10.  The Future of Pulmonary Vein Isolation - Single-shot Devices, Remote Navigation or Improving Conventional Radiofrequency Delivery by Contact Monitoring and Lesion Characterisation?

Authors:  David Filgueiras-Rama; Jose L Merino
Journal:  Arrhythm Electrophysiol Rev       Date:  2013-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.