Literature DB >> 19492715

Influence of cavity lining and remaining dentin thickness on the occurrence of postoperative hypersensitivity of composite restorations.

Florian Wegehaupt1, Herbert Betke, Nicole Solloch, Ulrike Musch, Annette Wiegand, Thomas Attin.   

Abstract

PURPOSE: To investigate the influence of the remaining dentin thickness after cavity preparation, calcium hydroxide lining, and two restorative systems on the occurrence of postoperative pain or hypersensitivity.
MATERIALS AND METHODS: One hundred twenty-three fillings were placed in 123 healthy patients. The remaining dentin thickness after caries excavation was measured with the Prepometer device at the deepest area of the cavity. The cavities were allocated to three different groups (shallow, medium, and deep) on the basis of the Prepometer results. The decision to use a calcium hydroxide liner or not was made by tossing a coin. Cavities which were to be later treated with an indirect restoration were restored with a buildup material. The other cavities were treated with a hybrid composite. After 6 months, the patients were re-examined and interviewed concerning postoperative pain incidents or hypersensitivity. A logistic regression was performed for the statistical analysis.
RESULTS: Logistic regression showed no statistically significant influence of any of the three different variables "cavity depth", "calcium hydroxide liner" and "restorative material" on the occurrence of pain or hypersensitivity.
CONCLUSION: The occurrence of pain or hypersensitivity does not depend on the remaining dentin thickness, calcium hydroxide lining, or the restorative system used in the present study.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19492715

Source DB:  PubMed          Journal:  J Adhes Dent        ISSN: 1461-5185            Impact factor:   2.359


  7 in total

1.  Restoration variables and postoperative hypersensitivity in Class I restorations: PEARL Network findings. Part 2.

Authors:  Peter Blanchard; Ying Wong; Abigail G Matthews; Donald Vena; Ronald G Craig; Frederick A Curro; Van P Thompson
Journal:  Compend Contin Educ Dent       Date:  2013-04

2.  Effectiveness of a resin-modified glass ionomer liner in reducing hypersensitivity in posterior restorations: a study from the practitioners engaged in applied research and learning network.

Authors:  Brad Strober; Analia Veitz-Keenan; Julie Ann Barna; Abigail G Matthews; Donald Vena; Ronald G Craig; Frederick A Curro; Van P Thompson
Journal:  J Am Dent Assoc       Date:  2013-08       Impact factor: 3.634

3.  Dental cavity liners for Class I and Class II resin-based composite restorations.

Authors:  Andrew B Schenkel; Analia Veitz-Keenan
Journal:  Cochrane Database Syst Rev       Date:  2019-03-05

Review 4.  Dental cavity liners for Class I and Class II resin-based composite restorations.

Authors:  Andrew B Schenkel; Ivy Peltz; Analia Veitz-Keenan
Journal:  Cochrane Database Syst Rev       Date:  2016-10-25

5.  Biological response to self-etch adhesive after partial caries removal in rats.

Authors:  Adriana Fernandes Da Silva; Marcelo Rocha Marques; Wellington Luiz De Oliveira Da Rosa; Sandra Beatriz Chaves Tarquinio; Pedro Luiz Rosalen; Silvana Pereira Barros
Journal:  Clin Oral Investig       Date:  2018-01-29       Impact factor: 3.573

6.  Postoperative hypersensitivity and its relationship to preparation variables in Class I resin-based composite restorations: findings from the practitioners engaged in applied research and learning (PEARL) Network. Part 1.

Authors:  Gary Berkowitz; Howard Spielman; Abigail Matthews; Donald Vena; Ronald Craig; Frederick Curro; Van Thompson
Journal:  Compend Contin Educ Dent       Date:  2013-03

7.  Comparison of the Estimated Radiographic Remaining Dentine Thickness with the Actual Thickness Below the Deep Carious Lesions on the Posterior Teeth: An in vitro Study.

Authors:  Nouf Al Jhany; Banin Al Hawaj; Alanoud Al Hassan; Zhoor Al Semrani; Mohammed Al Bulowey; Shahzeb Ansari
Journal:  Eur Endod J       Date:  2019-11-26
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.