OBJECTIVE: This study compares the visual performance of spherical and aspherical intraocular lenses (IOLs) by measuring higher-order aberration and contrast sensitivity (CS) values.
DESIGN: Prospective controlled study. PARTICIPANTS: Fifty-seven patients with age-related cataract (61 eyes).
METHODS: Patients were randomly allocated to 1 of 3 groups and implanted with either aspherical IOLs, Acrysof IQ (SN60WF) or Tecnis Z9001, or a spherical IOL, Acrysof Natural. Patients underwent routine examinations, including visual acuity, slit-lamp checks, and best-corrected visual acuity (BCVA), as well as measurement of higher-order aberrations and CS values, preoperatively and at 1 week, 1 month, and 2 months postoperatively.
RESULTS: All the patients had a BCVA better than 20/30 postoperatively. The spherical aberrations of the IQ group and Tecnis group were both lower than in the Natural (control) group (IQ: p < 0.05; Tecnis: p < 0.05); there was no significant difference in coma and higher-order aberration. No statistically significant difference was found in spherical aberration, coma, or higher-order aberration between the IQ and Tecnis groups. Under glare conditions, the CS values of the 2 aspherical IOLs were obviously better (IQ: p < 0.05; Tecnis: p < 0.05) than the CS value of the spherical IOL group at low frequency (IQ: 6.3 degrees, Tecnis: 4.0 degrees); under non-glare conditions there was a significant difference in CS values between the aspherical IOL groups and the control group (IQ: p < 0.01; Tecnis: p < 0.01) at low frequency (both 6.3 degrees). There was no statistical difference between the IQ and the Tecnis groups with or without glare.
CONCLUSIONS: An aspherical IOL can effectively reduce spherical aberration after cataract surgery, enhance CS values, and improve visual quality compared with traditional spherical IOLs for age-related cataract. However, there was no statistically significant difference in postoperative aberration and CS values between the Acrysof IQ and Tecnis Z9001 aspherical IOLs.

Entities:  

Mesh:

Year:  2009        PMID: 19491981     DOI: 10.3129/i08-121

Source DB:  PubMed          Journal:  Can J Ophthalmol        ISSN: 0008-4182            Impact factor:   1.882


  5 in total

1.  New insight into visual function with aspherical intraocular lenses (IOLs): Tecnis ZCB00 and Acrysof SN60WF.

Authors:  Serena Salvatore; Stefano Lupo; Marcella Nebbioso; Yu-Hui Huang; Enzo Maria Vingolo
Journal:  Int Ophthalmol       Date:  2011-11-20       Impact factor: 2.031

Review 2.  Blue-light filtering intraocular lenses (IOLs) for protecting macular health.

Authors:  Laura E Downie; Ljoudmila Busija; Peter R Keller
Journal:  Cochrane Database Syst Rev       Date:  2018-05-22

3.  A comparative study on visual and optical performance of Akreos AO and Kontur AB IOLs after phacoemulsification cataract surgery.

Authors:  Hamid Gharaee; Masoud Zabihifard; Alireza Eslampour; Samira Hassanzadeh; Masoud Shafiee
Journal:  J Curr Ophthalmol       Date:  2016-03-28

4.  Multifocal Toric Intraocular Lens for Traumatic Cataract in a Child.

Authors:  Yanfeng Zeng; Licheng Fan; Peirong Lu
Journal:  Case Rep Ophthalmol       Date:  2016-10-11

5.  Aspheric intraocular lenses implantation for cataract patients with extreme myopia.

Authors:  Yanwen Fang; Yi Lu; Aizhu Miao; Yi Luo
Journal:  ISRN Ophthalmol       Date:  2014-03-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.