Literature DB >> 19491635

Dynamic MRA with four-dimensional time-resolved angiography using keyhole at 3 tesla in head and neck vascular lesions.

Hemant Parmar1, Marko K Ivancevic, Nancy Dudek, Dheeraj Gandhi, Suresh K Mukherji.   

Abstract

Conventional MRA provides inadequate visualization of the dynamic features of blood flow in vascular lesions of the head and neck. Four-dimensional time-resolved angiography using keyhole (4D-TRAK) is a new technique of performing contrast-enhanced MRA. By combining parallel imaging with sensitivity encoding (SENSE) with the keyhole imaging technique and a high field strength (3 T) magnet, we have been able to obtain detailed hemodynamic information similar to that obtained via catheter angiography with digital subtraction (DSA), but without the risks associated with ionizing radiation exposure, iodizing contrast agents, or catheterization itself.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19491635     DOI: 10.1097/WNO.0b013e3181a58c20

Source DB:  PubMed          Journal:  J Neuroophthalmol        ISSN: 1070-8022            Impact factor:   3.042


  4 in total

1.  Dynamic MR angiography (MRA) of spinal vascular diseases at 3T.

Authors:  Maria Isabel Vargas; Duy Nguyen; Magalie Viallon; Zolt Kulcsár; Enrico Tessitore; Benedict Rilliet; Daniel Rufenacht; Karl Lovblad
Journal:  Eur Radiol       Date:  2010-05-16       Impact factor: 5.315

2.  A feasible high spatiotemporal resolution breast DCE-MRI protocol for clinical settings.

Authors:  Luminita A Tudorica; Karen Y Oh; Nicole Roy; Mark D Kettler; Yiyi Chen; Stephanie L Hemmingson; Aneela Afzal; John W Grinstead; Gerhard Laub; Xin Li; Wei Huang
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

3.  Evaluation of brain and head and neck tumors with 4D contrast-enhanced MR angiography at 3T.

Authors:  S Nishimura; T Hirai; Y Shigematsu; M Kitajima; M Morioka; Y Kai; R Minoda; H Uetani; R Murakami; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2011-11-24       Impact factor: 3.825

4.  Magnetic Resonance Angiography in the Diagnosis of Cerebral Arteriovenous Malformation and Dural Arteriovenous Fistulas: Comparison of Time-Resolved Magnetic Resonance Angiography and Three Dimensional Time-of-Flight Magnetic Resonance Angiography.

Authors:  Yu-Ching Cheng; Hung-Chieh Chen; Chen-Hao Wu; Yi-Ying Wu; Ming-His Sun; Wen-Hsien Chen; Jyh-Wen Chai; Clayton Chi-Chang Chen
Journal:  Iran J Radiol       Date:  2016-03-28       Impact factor: 0.212

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.