Literature DB >> 19488465

Flexural strength and hardness of direct and indirect composites.

Márcia Borba1, Alvaro Della Bona, Dileta Cecchetti.   

Abstract

The objective of this study was to evaluate the flexural strength (sigma f) and hardness (H) of direct and indirect composites, testing the hypotheses that direct resin composites produce higher sigma f and H values than indirect composites and that these properties are positively related. Ten bar-shaped specimens (25 mm x 2 mm x 2 mm) were fabricated for each direct [D250 - Filtek Z250 (3M-Espe) and D350 - Filtek Z350 (3M-Espe)] and indirect [ISin - Sinfony (3M-Espe) and IVM - VitaVM LC (Vita Zahnfabrik)] materials, according to the manufacturer's instructions and ISO4049 specifications. The sigma f was tested in three-point bending using a universal testing machine (EMIC DL 2000) at a crosshead speed of 0.5 mm/min (ISO4049). Knoop hardness (H) was measured on the specimens' fragments resultant from the sigma f test and calculated as H = 14.2P/l(2), where P is the applied load (0.1 kg; dwell time = 15 s) and l is the longest diagonal of the diamond shaped indent (ASTM E384). The data were statistically analyzed using Anova and Tukey tests (alpha = 0.05). The mean sigma f and standard deviation values (MPa) and statistical grouping were: D250 - 135.4 +/- 17.6a; D350 - 123.7 +/- 11.1b; ISin - 98.4 +/- 6.4c; IVM - 73.1 +/- 4.9 d. The mean H and standard deviation values (kg/mm(2)) and statistical grouping were: D250 - 98.12 +/- 1.8a; D350 - 86.5 +/- 1.9b; ISin - 28.3 +/- 0.9 c; IVM - 30.8 +/- 1.0 c. The direct composite systems examined produce higher mean sigma f and H values than the indirect composites, and the mean values of these properties were positively correlated (r = 0.91), confirming the study hypotheses.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19488465     DOI: 10.1590/s1806-83242009000100002

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  9 in total

1.  An In vitro Evaluation of Flexural Bond Strength of Indirect Composites Fused to Metal.

Authors:  N Sunitha; Padma Ariga; Ashish R Jain; Jacob Mathew Philip
Journal:  J Indian Prosthodont Soc       Date:  2013-03-19

2.  Effect of Additional Light Curing on Colour Stability of Composite Resins.

Authors:  Kubra Alan Unsal; Emel Karaman
Journal:  Int Dent J       Date:  2021-08-16       Impact factor: 2.607

3.  Microhardness of different resin cement shades inside the root canal.

Authors:  Valeria Vignolo; Maria-Victoria Fuentes; Miguel-Angel Garrido; Jesús Rodríguez; Laura Ceballos
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-09-01

4.  Indirect resin composites.

Authors:  Suresh Nandini
Journal:  J Conserv Dent       Date:  2010-10

5.  Telescopic Overdenture and Implant Supported Fixed Partial Denture: A Pragmatic Treatment Approach.

Authors:  Doğu Ömür Dede; M Cenk Durmuşlar; Onur Şahın; Ayşegül Köroğlu; Özer İşısağ
Journal:  Case Rep Dent       Date:  2015-05-27

6.  Assessing degradation of composite resin cements during artificial aging by Martens hardness.

Authors:  Stefan Bürgin; Nadja Rohr; Jens Fischer
Journal:  Head Face Med       Date:  2017-05-19       Impact factor: 2.151

7.  Surface Properties of Polymer Resins Fabricated with Subtractive and Additive Manufacturing Techniques.

Authors:  Amal S Al-Qahtani; Huda I Tulbah; Mashael Binhasan; Maria S Abbasi; Naseer Ahmed; Sara Shabib; Imran Farooq; Nada Aldahian; Sidra S Nisar; Syeda A Tanveer; Fahim Vohra; Tariq Abduljabbar
Journal:  Polymers (Basel)       Date:  2021-11-24       Impact factor: 4.329

8.  Three-year clinical performance of two indirect composite inlays compared to direct composite restorations.

Authors:  Nurcan Ozakar-Ilday; Yahya-Orcun Zorba; Mehmet Yildiz; Vildan Erdem; Nilgun Seven; Sezer Demirbuga
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-05-01

9.  Mechanical properties of direct and indirect composites after storage for 24 hours and 10 months.

Authors:  Paula Barbosa Alves; William Cunha Brandt; Ana Christina Claro Neves; Leonardo Gonçalves Cunha; Lais Regiane Silva-Concilio
Journal:  Eur J Dent       Date:  2013-01
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.