| Literature DB >> 1948378 |
C J Kalkman1, S A ten Brink, H D Been, J G Bovill.
Abstract
The effects of anesthetic technique (nitrous oxide or propofol) and high-pass digital filtering on within-patient variability of posterior tibial nerve somatosensory cortical evoked potentials (PTN-SCEP) were compared prospectively in two groups of 20 patients undergoing spinal surgery. Average P1N1 amplitude was significantly higher and P1N1 amplitude variability lower during propofol/alfentanil anesthesia than during nitrous oxide/alfentanil anesthesia. Off-line 30-Hz high-pass digital filtering significantly reduced P1N1 amplitude variability without decreasing P1N1 amplitude. In 93 patients studied retrospectively, a significant negative logarithmic correlation (r = -0.77) was observed between P1N1 amplitude and P1N1 amplitude variability. This study shows the importance of maintaining the highest possible PTN-SCEP amplitudes during spinal surgery. Propofol/opioid anesthesia may be an alternative anesthetic technique to nitrous oxide/opioid anesthesia during spinal cord function monitoring.Entities:
Mesh:
Substances:
Year: 1991 PMID: 1948378 DOI: 10.1097/00007632-199108000-00010